5. Operation
On/Off/Charger Only Switch
The switch is located on the underside to the bottom right of the product.
The switch has three positions. The centre position 0 is Off. The I position is On, and the II position is Charger Only.
When switched to 'I / On' (rocked towards the front of the unit), the product will come into operation and the inverter is
fully functional.
If an AC voltage is connected to the 'AC in' terminal, it will be switched through to the 'AC out' terminal, if within
specifications. The inverter will switch off, and the charger commences charging. 'Bulk', 'Absorption' or 'Float' will display,
depending on the charger mode.
If the voltage at the 'AC-in' terminal is rejected, the inverter will switch on.
When the switch is switched to 'II / Charger Only', only the battery charger of the Multi will operate (if mains voltage is
present). In this mode input voltage also is switched through to the 'AC out' terminal.
NOTE: When only the charger function is required, ensure that the switch is switched to 'II / Charger Only'. This prevents
the inverter from being switched on if the mains voltage is lost, thus preventing your batteries from running flat.
6. GX LCD Interface
The display screen will present useful information about your system.
6.1 On/off behaviour
When the product is switched off with the physical switch on the device or with the Remote On/Off terminals, then the GX
card is off as well. If you switch the product remotely, using a Digital Multi Control, then the GX card will remain powered.
Also when switching the inverter/charger off from within the GX menus, the GX card will remain powered.
Lastly, when the inverter/charger switches itself off due to an alarm, such as low battery or overtemperature, then the GX
card will remain powered and functional as well.
6.2 Push button behaviour
When the GX Card is on, pushing the button beside the screen will activate the backlight. The backlight will turn itself off
after 5 minutes.
Once the backlight has been activated, pushing the button again will cycle through the available display options. Some
options will be displayed automatically, and others require a button push to display.
6.3 Information displayed
Solar Power, Voltage and Charge state (if connected)
ESS/DVCC reason codes (if active)
Solar Daily Yield
Inverter/charger charge state (eg Bulk, ESS)
Battery State of Charge, Power and Voltage
Network IP Address and Connection Type (if connected).
AC input and output Power
In a system with more than one phase, there will be additional AC input and output information available, eg
Phase 1 AC input Voltage and Power.
Phase 1 AC output Voltage and Power.
Phase 2 AC input Voltage and Power.
Phase 2 AC output Voltage and Power.
Phase 3 AC input Voltage and Power.
Phase 3 AC output Voltage and Power.
6.4 Error Code Display
If there is an error with the system, the error code will be displayed on the screen. The screen will display VE.Bus error
code numbers, and MPPT error codes (if connected).
Basic information about the VE.Bus Error codes are in the Error Indications section.
For further details about the error codes please see:
VE.Bus Error Codes
MPPT Error Codes
The error will display until it is cleared.
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Victron EasySolar-II 48 3000 35-32 MPPT 250 70 GX wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info