an extremely high charging current with
respect to battery capacity, so that bulk
time is insufficient.
The battery is overcharged.
The absorption voltage is set to an
incorrect level (too high).
Set the absorption voltage to the correct
level.
The float voltage is set to an incorrect
level (too high).
Set the float voltage to the correct level.
Poor battery condition.
Replace the battery.
The battery temperature is too high (due
to poor ventilation, excessively high
environmental temperature, or
excessively high charging current).
Improve ventilation, install batteries in a
cooler environment, reduce the charging
current,
and connect the temperature
sensor.
The charging current drops to 0 as soon
as the absorption phase initiates. Defective battery temperature sensor
Disconnect the temperature sensor plug
in the EasySolar-II GX. If charging
functions correctly after approximately 1
minute, the temperature sensor should
be replaced.
The battery is over-heated (+50°C)
Install the battery in a cooler
environment
Reduce the charging current
Check whether one of the battery cells
has an internal short circuit
11.2 VE.Bus error codes
A VE.Bus system can display various error codes. These codes are displayed on the front GX display screen.
To interpret a VE.Bus error code correctly, you should refer to the VE.Bus error codes documentation -
https://www.victronenergy.com/live/ve.bus:ve.bus_error_codes.
Code
Meaning:
Cause/solution:
1
Device is switched off because one of the other
phases in the system has switched off.
Check the failing phase.
3 Not all, or more than, the expected devices were
found in the system.
The system is not properly configured. Reconfigure the
system. If the error persists, possible communication cable
error. Check the cables and switch all equipment off, and then
on again.
4
No other device whatsoever detected.
Check the communication cables.
5
Overvoltage on AC-out.
Check the AC cables.
10 System time synchronisation problem occurred.
Should not occur in correctly installed equipment. Check the
communication cables.
14 Device cannot transmit data.
Check the communication cables (there may be a short
circuit).
17
One of the devices has assumed 'master' status
because the original master failed.
Check the failing unit. Check the communication cables.
18
Overvoltage has occurred.
Check AC cables.
22 This device cannot function as 'slave'.
This device is an obsolete and unsuitable model. It should be
replaced.
24 Switch-over system protection initiated.
Should not occur in correctly installed equipment. Switch all
equipment off, and then on again. If the problem recurs,
check the installation.
Possible solution: increase lower limit
of AC input voltage to 210 VAC (factory setting is 180 VAC)
25
Firmware incompatibility. The firmware of one the
connected devices is not sufficiently up to date to
operate in conjunction with this device.
1) Switch all equipment off. 2) Switch the device returning
this error message on. 3) Switch on all other devices one by
one until the error message reoccurs. 4) Update the firmware
in the last device that was switched on.
26 Internal error.
Should not occur. Switch all equipment off, and then on
again. Contact Victron Energy if the problem persists.
18

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Victron EasySolar-II 48 3000 35-32 MPPT 250 70 GX wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info