23
03. Select "Settings" with / .
04. Confirm with OK.
05. Select "Programs" with / .
06. Confirm with OK.
07. With / select the program you
want to rename (e.g. "Prog 1").
08. Confirm twice with OK.
09. Select "Rename" with / .
10. Confirm with OK.
11. Enter the required characters on
line "New name" with / .
12. Confirm respectively with OK.
Temperature adjustment
The displayed room temperature can
deviate from the actual room tempera-
ture if your Vitotrol 100 is installed in an
unfavourable position, e.g. on an exter-
nal wall or near a chimney. You can cor-
rect this temperature deviation with a
compensator.
Example:
The room temperature displayed by the
Vitotrol 100 is 2 ºC higher than the actual
room temperature. The correction is then
−
2 ºC.
1. Open the flap.
2. Press twice.
3. Select "Settings" with / .
4. Confirm with OK.
5. Select "Service" with / .
6. Confirm with OK.
7. With OK select the required value to
be set for "Ctrller offset".
8. Set the required value with / .
9. Confirm with OK.
10. Exit the menu with .
Control characteristics
The hysteresis controller is factory-set.
The hysteresis value influences the start
and stop times for "Heating" or "Not heat-
ing".
Example:
Set room temperature: 21 °C
Hysteresis: 0.6 °C (delivered condition).
Setting range: 0.2 to 1.0 °C.
Heating stops as soon as the actual
room temperature exceeds 21.3 °C.
Heating starts as soon as the actual
room temperature falls below 20.7 °C.
Further adjustments
Renaming programs
(cont.)
5592 620 GB