Brine/water heat pumps
Brine/water heat pumps utilise geothermal energy to
generate heat. The geothermal energy is transferred to
the refrigerant circuit using a heat transfer medium
(brine). Here, the temperatures necessary for central
heating and DHW heating are generated. Here too, a
compressor drives the refrigerant circuit.
To provide central cooling, the heat pump extracts heat
from your rooms and transfers it to the ground.
Brine/water heat pumps are installed inside the build-
ing.
Note
Brine/water heat pumps can have two stages. Two-
stage brine/water heat pumps have 2 compressors
which can be activated individually or simultaneously
subject to the requested heating output.
Depending on heat pump type, the two compressors
can be installed in a single casing or in 2 adjacent cas-
ing units. Both compressors are controlled by one
shared heat pump control unit.
Water/water heat pumps
Water/water heat pumps utilise e.g. groundwater to
generate heat, following the same principle as brine/
water heat pumps. The energy from the groundwater
reaches the refrigerant circuit via a heat transfer
medium.
With auxiliary components, a brine/water heat pump
can be used as a water/water heat pump.
Water/water heat pumps are installed inside the build-
ing.
Equipment and functions
The heat pump types differ in their equipment levels:
DHW cylinder
Electric booster heater (instantaneous heating water
heater)
High efficiency circulation pumps
The heat pump types differ in the available functions:
Number of heating circuits
Solar DHW heating
Central cooling
Noise reduction
Output control
Utilisation of power generated on site
Utilisation of excess power from the grid (Smart Grid)
Your contractor will have listed the equipment and
functions of your heating system in the form on
page 102.
Mechanical ventilation systems
Mechanical ventilation systems provide controlled ven-
tilation of detached houses or apartments.
If your Viessmann system includes mechanical ventila-
tion, the central ventilation unit can be controlled and
operated by the heat pump control unit.
Ventilation operation adapts automatically to your
requirements via a time program. "Economy mode"
and the "Holiday program" help you to save energy.
With "Intensive operation", you increase the air
changes in the building and quickly expel odours and
moisture to the outside.
The following central ventilation units are supported:
Vitovent 200-C
Vitovent 200-C is suitable for detached houses or
apartments with up to 120 m2 of living space.
Vitovent 200-C meets the requirements for passive
house use.
The ventilation unit can either be mounted on a wall or
installed on the ceiling.
As well as being controlled by the heat pump control
unit, ventilation can also be activated by a switch or
button (bathroom switch) connected to the ventilation
unit, e.g. if you need the highest ventilation level for a
short period.
Vitovent 200-W
Vitovent 200-W is suitable for detached houses or
apartments with up to 230 m2 of living space.
This ventilation unit is mounted on a wall.
To prevent moisture damage to the building, the venti-
lation unit adjusts the air changes automatically,
depending on the relative humidity in your rooms
(accessories required).
Vitovent 300-C
Vitovent 300-C is suitable for detached houses or
apartments with up to 90 m2 of living space.
Introductory information
Product information (cont.)
5817913
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Viessmann VITOTRONIC 200 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Viessmann VITOTRONIC 200

Viessmann VITOTRONIC 200 Bedienungsanleitung - Deutsch - 112 seiten

Viessmann VITOTRONIC 200 Bedienungsanleitung - Holländisch - 112 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info