TESTING THE SYSTEM
54 D-304829 PowerMaster-10/30 G2 User's Guide
9. Testing the System
Periodic Test
The components of your security system are designed to be maintenance-free as much as possible.
Nevertheless, it is mandatory to test the system at least once a week and after an alarm event to verify that all
system sirens, detectors, keyfobs, keypads and other peripherals function properly. Proceed as described in this
section and if there is any problem, notify your installer at once.
The test is performed in three parts:
Siren Test: Each siren of the system is automatically activated for 3 seconds (outdoor sirens with low volume).
In addition, the system tests the siren of enrolled smoke sensors.
Temperature Sensor Test: When Temperature Sensors are enrolled in the system, the control panel displays
the temperature of each zone in Celsius or Fahrenheit.
Other Device Test: Each of the other devices in the system is activated by the user and the display indicates
which devices were not yet tested. The "it's me" indication helps to identify the untested devices if necessary.
A counter also indicates the number of devices that remain untested.
Carefully read the section titled "Additional Information" according to the indicated references
1
etc –
see table at end of this section.
A. To Enter the Periodic Test Menu
1. READY 00:00
Make sure the system is disarmed and then press the button
repeatedly until the display reads "PERIODIC TEST" and press .
1
PERIODIC TEST
2.
ENTER CODE:
The screen will now prompt you to enter your user code.
3.
CODE
Enter your User Code.
2
3
Go to step 4
B. To Test the Sirens
4. SIRENS TEST The display now reads [SIRENS TEST].
5.
To initiate the siren test press .
Immediately after pressing ,
all 4 LED's on the panel should light (LED test).
4
SIREN N
The display now reads [SIREN N], where "N" indicates the zone location
assigned to the siren that is currently being tested.
5
First the panel siren sounds for 3 seconds after which the PowerMaster
system will automatically repeat the procedure for the next siren enrolled in
the system until all sirens are tested.
6
You should listen to the sirens sounds and make sure that all sirens sound.
Once all the sirens have been tested, the control panel will now test the
sirens of smoke sensors that are enrolled in the alarm system. The display
now reads [Zxx: SMOKE SIREN], where "Zxx" indicates the zone number of
the smoke sensor, and alternates with [<OK> TO CONTINUE]. During this
time, the siren of the tested smoke sensor will sound for up to one minute.
Press to test the siren of the next smoke sensor.
6. SIRENS TESTS END
When all the sirens test is complete, the display reads [SIREN TESTS END].
Press the or the button to confirm the test and then move to
the next step for zone temperature display.
or
C. To Display the Temperature
7. TEMPERATURE TEST The display now reads [TEMPERATURE TEST].
8.
To display the temperature of zones on the control panel, press .
7
Z01 24.5°
°°
°C
The control panel reads the temperature of each zone. The display alternates
55

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

visonic-powermaster-10-30-g2-version-18

Suche zurücksetzen

  • Koenten Sie mir bitte die Bedienungsanleitung von Powermaster 10/30 G2 version 18 auf Deutsch also e mail schicken danke
    JWALDBILLIG@vdl.lu Eingereicht am 21-1-2019 07:17

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Visonic PowerMaster-10-30 G2 Version 18 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Visonic PowerMaster-10-30 G2 Version 18

Visonic PowerMaster-10-30 G2 Version 18 Installationsanweisung - Holländisch - 112 seiten

Visonic PowerMaster-10-30 G2 Version 18 Bedienungsanleitung - Holländisch - 72 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info