D-304829 PowerMaster-10/30 G2 User's Guide 71
Message to Private
Phones
Tone Tone or voice
Ring Detection The unit does not support ring detection without
DC voltage present on the telephone lines.
The unit does not support ring detection without
DC voltage present on the telephone lines
E5. Physical Properties
PowerMaster-10 G2 PowerMaster-30 G2
Operating Temp.
Range
14°F to 120°F (-10°C to 49°C)
Note: For UL Listed product, the ambient
temperature is 32°F to 120°F (0°C to 49°C)
14°F to 120°F (-10°C to 49°C)
Note: For UL Listed product, the ambient
temperature is 32°F to 120°F (0°C to 49°C)
Storage Temp.
Range
-4°F to 140°F (-2C to 60°C) -4°F to 140°F (-20°C to 60°C)
Humidity 93% relative humidity, @ 30°C (86°F) 93% relative humidity, @ 30°C (86°F)
Size 196 x 180 x 55 mm (7-5/8 x 7 x 2 in.) 266 x 201 x 63 mm (10-7/16 x 7-7/8 x 2-1/2 in.)
Weight 658g (23 Oz) (with battery) 1.44Kg (3.2 pounds) (with battery)
Color White White
E6. Peripherals and Accessory Devices
PowerMaster-10 G2 PowerMaster-30 G2
Modules GSM/GPRS, IP (future use) GSM/GPRS, IP (future use)
Additional
wireless devices
30 detectors, 8 keyfobs, 8 keypads, 4 sirens,
4 repeaters, 8 proximity tags
64 detectors, 32 keyfobs, 32 keypads (10 KP-
250 PG2), 8 sirens, 4 repeaters , 32 proximity
tags
Wireless Devices
and peripherals
Magnetic Contact: MC-302 PG2, MC-302E
PG2, MC-302EL PG2, MC-302V PG2
Motion Detectors: Next PG2; Next K9 PG2,
TOWER-20 PG2, TOWER-32AM PG2 (not UL
listed), TOWER-32AM K9 PG2 (not UL listed),
TOWER-30AM PG2, TOWER-30AM K9 PG2,
CLIP PG2 (not UL listed), TOWER CAM PG2
PIR Camera Detectors: Next CAM PG2;
Next CAM-K9 PG2
Smoke Detector: SMD-426 PG2, SMD-427
PG2
GSM Module: GSM-350 PG2
(optional)
Keyfob: KF-234 PG2, KF-235 PG2 (not UL
listed)
Keypad: KP-140 PG2/KP-141 PG2 (with
proximity tag), KP-160 PG2, KP-250 PG2
1
Indoor Siren: SR-720 PG2, SR-720B PG2
Outdoor Sirens: SR-730 PG2, SR-740 PG2,
SR-740 HEX PG2
Repeater: RP-600 PG2
Gas: GSD-441 PG2 (not UL listed), GSD-442
PG2
Glass-break: GB-501 PG2 (not UL listed)
Temperature: TMD-560 PG2 (not UL listed)
Flood: FLD-550 PG2 (not UL listed)
Shock: SD-304 PG2 (not UL listed)
Note: UL requires that when using remote
smoke/CO detectors and repeaters, each
detector must be within range (STRONG) of 2
repeaters at all times (for path redundancy –
UL 985).
Magnetic Contact: MC-302 PG2, MC-302E
PG2, MC-302EL PG2, MC-302V PG2
Motion Detectors: Next PG2; Next K9 PG2,
TOWER-20 PG2, TOWER-32AM PG2 (not UL
listed), TOWER-32AM K9 PG2 (not UL listed),
TOWER-30AM PG2, TOWER-30AM K9 PG2,
CLIP PG2 (not UL listed), TOWER CAM PG2
PIR Camera Detectors: Next CAM PG2;
Next CAM-K9 PG2
Smoke Detector: SMD-426 PG2, SMD-427
PG2
GSM Module: GSM-350 PG2
(optional)
Keyfob: KF-234 PG2, KF-235 PG2 (not UL
listed)
Keypad: KP-140 PG2/KP-141 PG2 (with
proximity tag), KP-160 PG2, KP-250 PG2
1
Indoor Siren: SR-720 PG2, SR-720B PG2
Outdoor Sirens: SR-730 PG2, SR-740 PG2,
SR-740 HEX PG2
Repeater: RP-600 PG2
Gas: GSD-441 PG2 (not UL listed), GSD-442
PG2
Glass-break: GB-501 PG2 (not UL listed)
Temperature: TMD-560 PG2 (not UL listed)
Flood: FLD-550 PG2 (not UL listed)
Shock: SD-304 PG2 (not UL listed)
Note: UL requires that when using remote
smoke/CO detectors and repeaters, each
detector must be within range (STRONG) of 2
repeaters at all times (for path redundancy –
UL 985).
1
KP-250 PG2 is not relevant for UL installations
72

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

visonic-powermaster-10-30-g2-version-18

Suche zurücksetzen

  • Koenten Sie mir bitte die Bedienungsanleitung von Powermaster 10/30 G2 version 18 auf Deutsch also e mail schicken danke
    JWALDBILLIG@vdl.lu Eingereicht am 21-1-2019 07:17

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Visonic PowerMaster-10-30 G2 Version 18 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Visonic PowerMaster-10-30 G2 Version 18

Visonic PowerMaster-10-30 G2 Version 18 Installationsanweisung - Holländisch - 112 seiten

Visonic PowerMaster-10-30 G2 Version 18 Bedienungsanleitung - Holländisch - 72 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info