D-304829 PowerMaster-10/30 G2 User's Guide 69
PowerMaster-10 G2 PowerMaster-30 G2
Real Time Clock
(RTC)
The control panel keeps and displays time and
date. This feature is also used for the log file by
providing the date and time of each event
The control panel keeps and displays time and
date. This feature is also used for the log file by
providing the date and time of each event
Battery Test Once every 10 seconds Once every 10 seconds
E2. Wireless
PowerMaster-10 G2 PowerMaster-30 G2
RF Network PowerG 2-way synchronized Frequency
Hopping (TDMA / FHSS)
PowerG 2-way synchronized Frequency
Hopping (TDMA / FHSS)
Frequency bands
(MHz)
433 – 434 868 - 869 912 – 919* 433 – 434 868 - 869 912 – 919*
Hopping
frequencies
8 4 50 8 4 50
Region Worldwide Europe North
America and
selected
countries
Worldwide Europe North
America and
selected
countries
Encryption AES-128
Note: AES-128 bit encryption for
communication between control unit and
initiating devices is not suitable as a means of
Encrypted Line Security in UL Listed product.
AES-128
Note: AES-128 bit encryption for
communication between control unit and
initiating devices is not suitable as a means of
Encrypted Line Security in UL Listed product.
* For UL Listed product, enable this frequency band.
E3. Electrical
PowerMaster-10 G2 PowerMaster-30 G2
External AC/AC
adaptor
Europe: 230VAC 50Hz input, 9VAC 700mA
output.
USA: 120VAC 60Hz input, 9VAC 1000mA
output.
NA
External AC/DC
adaptor
NA External (wall-mounted) switching power
supply 100VAC to 240VAC, 50/60 Hz, 0.5A /
12.5 VDC, 1.2A
Internal AC/DC Internal switching power supply:
Input: 100-240VAC, 0.12 A Max.
Output: 7.5VDC, 1.2A Max.
Internal switching power supply:
Input: 100-240VAC, 0.75A
Output: 12.5 VDC, 1.6A.
Current Drain Approx. 240 mA standby at the beginning
(power ON) and then goes down to 90 mA
standby, 1200 mA peak at full load.
Approx. 260 mA standby at the beginning
(power ON) and then goes down to 60 mA,,
1400 mA max. current drain during alarm.
Low Battery
Threshold
4.8 V 7.2 V (6-cell battery pack)
9.6 V (8-cell battery pack)
Backup Battery
Pack
4.8V 1300 mAh, rechargeable NiMH battery
pack, p/n GP130AAM4YMX, manufactured
by GP or p/n LTT-1300AA4Y, manufactured
by LTT.
4.8V 1800 mAh, rechargeable NiMH battery
pack, p/n GP180AAH4YMX, manufactured
by GP or p/n LTT-1800AA4Y, manufactured
by LTT.
4.8V 2200 mAh, rechargeable NiMH battery
pack, p/n GP220AAH4YMX, manufactured
by GP or p/n LTT-2300AA4Y, manufactured
by LTT. For UL Listed product, use these
batteries only.
Caution! Risk of explosion if battery is
replaced by an incorrect type. Dispose of
used batteries according to the
manufacturer's instructions.
Note: For compliance with CE standards the
battery capacity must be at least 1300 mAh.
Backup Battery Options:
Backup
period
Maximum external devices current (1)
1300 mAh
6 Battery
Pack (2)
1800 mAh
8-Battery
Pack (3)
2200 mAh
8-Battery
Pack (4)
4h 180 mA 300 mA 380 mA
8h 70 mA 125 mA 160 mA
12h 35 mA 70 mA 95 mA
24h max
backup w/o
load 22
hours
12 mA 25 mA
32h no backup 0 mA 10 mA
39h no backup no backup 0 mA
(1) The external devices must be connected
between 12V and ground. The current for
each specified backup period can be
drawn from the batteries with the internal
GSM and the proximity reader connected
to the
PowerMaster
-
30
G2.
70

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

visonic-powermaster-10-30-g2-version-18

Suche zurücksetzen

  • Koenten Sie mir bitte die Bedienungsanleitung von Powermaster 10/30 G2 version 18 auf Deutsch also e mail schicken danke
    JWALDBILLIG@vdl.lu Eingereicht am 21-1-2019 07:17

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Visonic PowerMaster-10-30 G2 Version 18 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Visonic PowerMaster-10-30 G2 Version 18

Visonic PowerMaster-10-30 G2 Version 18 Installationsanweisung - Holländisch - 112 seiten

Visonic PowerMaster-10-30 G2 Version 18 Bedienungsanleitung - Holländisch - 72 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info