580333
26
Zoom out
Zoom in
Vorherige Seite
1/36
Nächste Seite
26 D-302989
4.10.1 GPRS Communication Test
The GPRS Communication diagnostic procedure tests
GSM/GPRS communication and reports the diagnostic
result. In case of communication failure, detailed
information of the failure is reported.
The following GSM/ GPRS messages are reported:
Message Description
Unit is OK GSM / GPRS is functioning correctly.
GSM comm.
loss
The GSM/GPRS module does not
communicate with the Panel
Pin code fail Missing or wrong PIN code.
(Only if SIM card PIN code is enabled.)
GSM net. fail Unit failed with registration to local
GSM network.
SIM card fail SIM not installed or SIM card failure.
GSM not
detected
GSM auto enroll failed to detect
GSM/GPRS module.
No GPRS
service
The SIM card does not have the GPRS
service enabled.
GPRS conn.
fail
Local GPRS network is not available
or, wrong setting to GPRS APN, user
and/or password.
Srvr
unavailable
IPMP Receiver cannot be reached –
Check the Server IP
IP not defined Server IP #1 and #2 are not configured.
APN not
defined
APN is not configured.
SIM card
locked
After entering a wrong PIN code 3
consecutive times the SIM is locked.
To unlock it enter a PUK number. The
PUK number cannot be entered by the
PowerMaxExpress.
Denied by
server
The IPMP denies the connection
request. Check that the Panel is
registered to the IPMP Receiver.
4.10.2 LAN Connection Test
The LAN Connection diagnostic procedure tests
Broadband Module communication to the IPMP and
reports the diagnostic result. In case of communication
failure, detailed information of the failure is reported.
If the Broadband Module is not registered to the
PowerMaxExpress, the menu "LAN CONNECT.TEST" will
not be displayed.
The following LAN messages are reported:
Message Description
Unit is ok Broadband Module is functioning
correctly.
Test aborted The diagnostic test is aborted, as
follows:
AC failure – Broadband Module is
set to OFF mode.
Broadband Module has not
completed the power-up procedure.
In this case, the installer should wait
a maximum of 30 seconds before
re-testing.
Comm. loss The RS-232 serial interface between
the Broadband Module and the
PowerMaxExpress failed.
Rcvr Ip
missing
Receivers IP 1 and 2 settings are
missing in the PowerMaxExpress.
Cable
unplugged
The Ethernet cable is not connected
to the Broadband Module.
Check lan
config
This message appears in any of the
following cases:
Incorrect Broadband Module IP has
been entered.
Incorrect subnet mask has been
entered.
Incorrect default gateway has been
entered.
DHCP server failure.
Rcvr#1
UnReach.
Rcvr#2
UnReach.
Receiver 1 or 2 is inaccessible, as
follows:
Wrong receiver IP has been entered.
Receiver failure.
WAN Network failure.
Rcvr#1 UnReg.
Rcvr#2 UnReg.
The PowerMaxExpress unit is not
registered to IP receiver 1 or 2.
Broadband
Module
timeout err.
Broadband Module does not respond
to test result within 70 sec.
Invalid result Broadband Module responds with a
result code that is not recognized by the
PowerMaxExpress.
26

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Visonic PowerMax Express wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Visonic PowerMax Express

Visonic PowerMax Express Bedienungsanleitung - Holländisch - 35 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info