4.2 Chimney sweep function
WARNING USE AT OWN RISK:
The space heating is set up to maximum temperature to
prevent the burner from overheating. Some heating pipes
can be damaged at temperatures over 40°C!
The “chimney sweep” function is used for:
exhaust fume measurements at the heating system
to put maximum heating load on the system
(burn possible deposits in the burner, when run for
extended periods at partial load)
Attention safety rules when using the “chimney sweep
function:
1. Chimney sweep” function is activated for the time it is
needed.
During the Chimney sweep function the outputs:
P3, (with MULTIPLEX P4, P5, P7, P9, P10) will be turned
ON
P1, P2, (With MULTIPLEX P6, P8) will be turned OFF
WARNING: don’t overheat your system!
2. When the “Chimney sweep” is finished, Switch Off the
LCD+ controller for a few seconds. Off (active)
3. Before restarting the LCD+ controller check all elements
(pipes…) of the installation to be ensure that no damages
has occured,
Automatic (active)
4.3 Manual testing operation:
- In this mode it is possible to check the operation of Pump1,
Pump2/Valve and extra outputs. It is also possible to check the
values of all sensors inputs.
N.B. the sensor input not used are noted with the maximum
value.
- To activate the output select the desired line with (+) or (-)
and press (►) to highlight this line. Now with (+) or (-)the
different outputs can be tested.
- The pump activation starts with the minimum value xx%
adjusted on the “Setting” menu (see Pump speed) and can be
increased from 5% up to 100% in steps with (+) key.
Note: When you exit this menu all outputs are turned off.
- Press (◄) repeatedly to return to the main menu.
5 Operation hours Menu
In this menu it is possible to observe the cumulative totals for
operating hours, dT, power and energy input registered by the
controller.
The controller has the ability to record and store all data and
parameters of the installation on an SD card. This enables the
analysis of the efficiency of the solar installation and also
allows the pre-configuration of the installation parameters on
your computer. (This functions require a special Watts Data
Logger Kit with software. Watts order number P04189)
After the SD card is inserted, it must be activated:
Select the SD card line with (+) or (-) and press (►) to highlight
this line. Now with (+) or (-) you can activate or deactivate the
SD card.
SD card Deactivate => the SD card is ready to work
SD card Activate => the SD card is off or deactivated
Attention:
- The recording of the data on the SD card is only possible if
the SD card is inserted and activated. (All data already
registered by the solar controller before will not be recorded
on the computer)
- A small SD card logo on the main screen is visible if the SD
card is inserted and activated.
Important: Do not unplug the SD card before deactivate it.
5.1 Data logger set with WATTS software and SD
card
The controller has the ability to record and store all data and
parameters of the installation on an SD card. This enables the
analysis of the efficiency of the solar installation and also
allows the pre-configuration of the installation parameters on
your computer. (This functions require a special Watts Data
Logger Kit with software. Watts order number P04189)
a) Systems and parameters for the installation
(Schemes, extra functions, speed control, priority tank, flow
sensor …)
- Set the parameters for the system on the computer and
transfer the data to the controller
- Analyze the recorded parameters from the SD card on
the computer
This requires hardware and software: SD card set
- Record the current operation data from the solar system
on the SD card
This requires hardware and software: SD card set; SD card
max. 2GB, no SDHC
b) Operation data; system control and measuring of
energy
(The data of the system can be recorded, as energy,
operation hours, temperatures of the sensors, pump speed and
priority time break, flow …)
- Record permanently the operation data on the SD card
Requires Hard and Software: SD card set
- Analyze of the operation data; system control and
measuring of energy on a PC
Requires Hard and Software: SD card set
Attention::
For the following functions the special Watts Data Logger
Kit no. P04189 is required
- Set the parameters for the system on your computer and
transfer the data to the controller
- Analyze the recorded parameters from the SD card on the
computer
- Analyze of the operation data; system control and
measuring of energy on the PC
For the following functions there is no special Watts Data
Logger Kit required
(For this function only an empty SD card is required. Not
included in the controller)
- Recording permanently the Operation data on the SD card
- Recording the current operation data from the controller on
the SD card.
 Manual testing------------- --
P1 0%
P2 0%
P3 0
T1 _ _ °C T2 _ _°C T3 _ _ °C
T4_ _°C T5 _ _ °C
GT _ °C F _ _ L/min P _ _ Bar
 Operation h------------ -- --- --
Operation _ _ h
dT _ _°C
Power _ _kW
Energy _ _kWh
SD card Deactivated
16

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Watts Solar Controller LCD PLUS wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info