Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany
www.AKTOBIS.de
Email: info@aktobis.de
Functional description:
1.) On/Off switch 8.) Display panel for A) Humidity
2.) "Tank full" signal light and B) Target humidity value (flashing)
3.) "Defrost" signal light (unit in defrost mode) 9.) Button for selecting the air circulation (strong/weak)
4.) "Air circulation strength" signal lights 10.) Timer button (1-24 hours)
5.) "WLAN function" signal light 11.) Setting button for "value up" (▲)
6.) "Timer activated" signal light 12.) Setting button for "value down" (▼)
7.) Display field for A) temperature and B) timer (flashing)
Instructions for use:
1. Commissioning
1.1. Mounting the castors:
Remove the four (4) supplied and unassembled castors from the condensation tank.
Then lay the construction dryer on the floor so that the castors can be attached to the
bottom of the unit. Now push the castors into the device in the direction of the arrow
until they lock into place. Now put the construction dryer back in place and wait approx.
30 minutes so that the internal coolant can settle again.
1.2. Insert the mains plug properly into the socket.
1.3. Check that the condensation tank is properly seated in the building dryer. (When using
the dryer for the first time, the "condensation tank full" light may come on. Simply pull the
condensation tank out briefly and then push it back in again and you are ready to go).
1.4. Switch on the unit with the "On/Off switch". Now press the setting button for "Value down".
Now you can set your target humidity with the arrow keys (▼▲) as desired. The target
value of 30% humidity actually corresponds to continuous operation !!!
1.5. Use the air circulation selection button to choose between weak and strong
air circulation.
1.6. Optionally, you can select an automatic operating time between 1-24 hours with the timer key. Press the timer
button and then the setting button (▼▲) repeatedly until you have selected the desired number of hours. After
this timer time has elapsed, the building dryer switches off automatically! If you want to stop the timer before
the set time has elapsed, set it to zero again!