Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany
www.AKTOBIS.de
Email: Info@Aktobis.de
Instructions for use:
1. Commissioning
1.1. You need a suitable power cable for connection. This connection cable is not included in the scope of
delivery, please use a connection cable with the following specification for this purpose:
(1) Five-pole power connection 380V/415V (50/60Hz, 63A)
(2) Five-core power cable H07RN-F (5G 10 mm²)
(3) Five-pole power plug 380V/415V (50/60Hz, 63A)
1.2. Connect the power cable properly to the heater. To do this, open the protective flap of the five-pole power
connection (see fig. below). Now connect the plug head of the power cable to the socket provided for this
purpose on your unit. It is important that the power connection is firmly and properly seated in the connection
socket of the unit. Finally, connect the power plug properly to a power socket.
1.3. Select the desired unit power with the operating power adjustment knob (left-hand knob).
= Off
= Fan operation
= Level 1 (small operating power with 15 kW heating power)
= Level 2 (high operating power with 30 kW heating power)