GAS INSTRUcTIoNS (moDEL 320)
INSTALL GAS SUPPLY
General Specifications For Piping
Note: Contact your local municipality for building codes regulating outdoor
gas barbecue installations. In absence of Local Codes, you must conform to
the latest edition of the National Fuel Gas Code: ANSI Z 223.1/NFPA 54, or CAN/
CGA-B149.1, Natural Gas and Propane Installation Code. WE RECOMMEND THAT THIS
INSTALLATION BE DONE BY A PROFESSIONAL.
Some of the following are general requirements taken from the latest edition of the
National Fuel Gas Code: ANSI Z 223.1/NFPA 54, or CAN/CGA-B149.1, Natural Gas and
Propane Installation Code for complete specifications.
• Thisbarbecueisdesignedtooperateat7"ofwatercolumnpressure(.2526psi).
• Amanualshut-offvalvemustbeinstalledoutdoors,immediatelyaheadofthequick
disconnect.
• Anadditionalmanualshut-offvalveindoorsshouldbeinstalledinthebranchfuelline
in an accessible location near the supply line.
• Thequickdisconnectconnectstoa3/8"NPTthreadfromthegassource.Thequick
disconnect fitting is a hand-operated device that automatically shuts off the flow of
gas from the source when the barbecue is disconnected.
• Thequickdisconnectfittingcanbeinstalledhorizontally,orpointingdownward.
Installing the fitting with the open end pointing upward can result in collecting water
and debris.
• Thedustcovers(suppliedplasticplugs)helpkeeptheopenendsofthequick
disconnect fitting clean while disconnected.
• Pipecompoundshouldbeusedwhichisresistanttotheactionofnaturalgaswhen
connections are made.
• Theoutdoorconnectormustbefirmlyattachedtorigid,permanentconstruction.
m WARNING: Do not route the ten foot hose under a deck. The
hose must be visible.
Gas Line Piping
• Forthecorrectsizeandlengthofgaslinepipingrefertothelatesteditionofthe
National Fuel Gas Code: ANSI Z 223.1/NFPA 54, or CAN/CGA-B149.1, Natural Gas
and Propane Installation Code.
• Gaspipingmaybecoppertubing,typeKorL;polyethyleneplastictube,witha
minimumwallthicknessof.062";orstandardweight(schedule40)steelorwrought
iron pipe.
• Coppertubingmustbetin-linedifthegascontainsmorethan0.3gramsofhydrogen
sulfide per 100 cubic feet of gas.
• Plastictubingissuitableonlyforoutdoor,undergrounduse.
• Gaspipingincontactwithearth,oranyothermaterialwhichmaycorrodethepiping,
must be protected against corrosion in an approved manner.
• Undergroundpipingmusthaveaminimumof18"cover.
Test Connections
All connections and joints must be thoroughly tested for leaks in accordance with local
codes and all listed procedures in the latest edition of the National Fuel Gas Code: ANSI
Z 223.1/NFPA 54, or CAN/CGA-B149.1.
m DANGER
Do not use an open flame to check for gas leaks. Be sure
there are no sparks or open flames in the area while you
check for gas leaks. This will result in a fire or explosion
which can cause serious bodily injury or death and damage
to property.
7
8
This is a typical installation of a Weber
®
natural gas barbecue.
Local codes may require different installations.
INSIDE WALL
1 Gas Supply 2 Shut off
oUTSIDE WALL
3 Quick-Disconnect 4 3/8"PipeNipple
5 Reducing Coupling 6 1/2"PipeNipple
7 Locking Shut Off 8 Do Not Use
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Weber Genesis E 330 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Weber Genesis E 330

Weber Genesis E 330 Bedienungsanleitung - Deutsch - 32 seiten

Weber Genesis E 330 Installationsanweisung - Deutsch, Holländisch - 4 seiten

Weber Genesis E 330 Bedienungsanleitung - Holländisch - 32 seiten

Weber Genesis E 330 Installationsanweisung - Französisch, Italienisch - 4 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info