WP 80 / WSP 80:
The soldering iron WP 80 / WSP 80 is characterized by its
capacity for reachingthe soldering temperature quickly and
precisely. Its slim design and heating power of 80 watts
makes universal usage possible - from extremely fine to
high-temperature soldering work. Work can be continued
immediately after switching soldering tips, since the tempe-
rature is reached again quickly.
See "Accessories" for additional tools.
3. Commissioning
Place the soldering tool in the holder. Insert compressed air
hose with 6 mm outer diameter in the quick action coupling
(12). Provide supply of compressed air with 400 kPa (58 psi)
dry, oil-free compressed air or nitrogen (N2).
Warning:
When using nitrogen, attention must be paid to
satisfactory room ventilation.
Plug the electrical lead from the soldering tool in the 7 pole
socket (7) on the front panel and lock. Connect the compres-
sed air hose to the compressed air connection nipple (8).
Check that the mains voltage matches that on the rating
plate and that the mains switch (1) is in the off position. If the
mains voltage is correct, plug the control unit into the mains.
Warning:
Do not direct hot air soldering tools at people or
inflammable objects.
Switch on the unit at the mains switch (1). When the unit is
switched on, a self-test is performed during which all the
indicators (2) are illuminated. The temperature set (required
value) and the temperature scale (°C/°F) are then briefly dis-
played. The electronics then switch automatically to the dis-
play of the actual value. The red dot (5) on the display (2) illu-
minates. This dot serves as an optical regulation monitor.
Continuous illumination means that the system is heating
up. Flashing indicates that the operating temperature has
been reached.
Setting the temperature
The digital display (2) shows the actual value temperature.
By pressing the UP or DOWN key (3, 4) the digital display (2)
switches to the setpoint. The setpoint can be changed by
tapping or by firmly pressing the UP or DOWN button (3, 4)
in the desired direction. Pressing the button will change the
setpoint quickly. The digital display (2) returns automatically
to the actual value approximately 2 seconds after releasing
the button.
Adjusting the Air Flow Rate
The air flow rate required can be adjusted at the flow control
valve (9). Turning the control valve (9) to the left increases
the flow rate. Air is fed to the hot air soldering tool as long as
the finger operated switch is held down.
Standard setback for control unit WAD 101:
Setting back the set temperature to 150°C. The setback
time, which follows the switching of the soldering station to
standby mode, is 20 minutes. After three setback times
(60 minutes) the ”AUTO-OFF” function is activated. The
soldering tool is switched off (blinking line on the display).
English
Technical Data
Dimensions in mm: 166 x 134 x 101 (L x B x H)
Mains Voltage: 230 V / 50 Hz (120 V / 60 Hz)
Power Consumption WAD 101: 105 W
Power Consumption WAD 101IG: 150 W
Protection Class: 1 (Control Unit) and 3 (Soldering Tool)
Fuse: 230 V: T 630 mA (120 V: T 1,0 A)
Temperature Regulation: °C Version Hot Air 50°C - 550°C
Soldering Iron & inert gas soldering irons 50°C - 450°C
°F Version Hot Air 122°F - 999°F
Soldering Iron & inert gas soldering irons 122°F - 842°F
Precision: Hot Air ± 30°C (± 54°F)
Soldering Iron & inert gas soldering irons ± 9°C (± 17°F)
Flow Rate: Approx. 0 - 10 l/min
Control range of WAD 101IG: approx. 0 - 5 l/min.
Compressed Air: Inlet pressure 400 kPa (58 psi), oil-free, dry compressed air or nitrogen (N2)
Compressed Air Connection: Compressed air hose of 6 mm (0.24") diameter
Inert gas pressure: The inlet pressure is set permanently to 200 kPa by a pressure regulator.
The pressure regulator must not be adjusted.
25

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Weller WAD 101 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info