Setting: When switching on, hold the ”UP” key (3) until ON or
OFF appears in the display.
The setting is saved when the "UP" button is released.
Repeat this step to change.
Standard setback for control unit WAD 101IG
After placing the soldering iron on its stand, the nominal tem-
perature is reduced to 180°C and inert gas feed is shut off
after 2 min. The "AUTO-OFF" function is deactivated.
4. Equipotential bonding
The various circuit elements of the 3.5 mm jack bush make
4 variations possible:
Hard-grounded:
No plug (delivery form)
Equipotential bonding:
With plug, equalizer at center
contact (impedance 0 Ohms)
Potential free:
With plug
Soft-grounded:
With plug and soldered
resistance. Grounding via set
resistance value.
5. Instructions for use
External input unit WCB 1 and WCB 2 (optional)
The following functions are possible when using an external
input unit.
Offset:
The real temperature of the soldering iron can be changed by
± 40°C by input of a temperature offset.
Setback:
Reduction of the required temperature set to 150°C / 300°F
(standby). The set-back time, the time after which the
soldering station switches into standby mode, can be
adjusted from 0-99 minutes. The set-back condition is
indicated by a flashing actual value display. After a period
equal to three times the set-back time, „AUTO-OFF“ is
activated. The soldering iron is switched off (flashing dash on
the display). The set-back or auto-off condition is ended by
pressing a button or finger switch pressure. During this
process the required value set is briefly displayed.
Lock:
Locking the setpoint temperature. Settings cannot be
changed after the soldering station has been locked.
°C/°F:
Switching the temperature display from °C to °F, and vice
versa.
Window:
Limitation of the temperature range to max. ± 99°C based on
a locked temperature resulting from the "LOCK” function.
The locked temperature represents the median point of the
adjustable temperature range.
Cal:
Re-adjustment of the soldering station (WCB 2 only).
PC interface:
RS232 (WCB 2 only).
Temp. gauge:
Integrated temperature gauge for thermal element Type K
(WCB 2 only).
Hot Air Soldering Tool
The hot air nozzles are screwed into the heater element. To
change the nozzle use the 8 SW socket spanner and lock the
heater element with an open ended spanner.
Important:
The maximum thread depth is 5 mm (0.2").
A longer thread will irreparably damage the heater
element.
Nitrogen N2 reduces oxidation and flux remains active for
longer. We recommend the nitrogen N2 that is available in
steel bottles. The bottle must be equipped with a 0-10 bar
pressure reducer.
Soldering Iron
The transition between the heater element/sensor and the
soldering iron bit must not be degraded by dirt, foreign bodies
or damage because these will have an effect on the
precision of temperature regulation.
When heating up for the first time, wet the selectively tinna-
ble soldering iron bit with solder. This removes oxide layers
and soiling that have formed during storage. Always ensure
that the soldering iron bit is well tinned during breaks in sol-
dering and when placing in the holder. Do not use aggressi-
ve fluxes.
Important:
Always ensure that the soldering iron bit is correctly
seated.
English
19
26

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Weller WAD 101 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info