7 Error Analysis, Error Codes, Safety Functions and Safety
Devices
All stoves are equipped with numerous safety devices. Errors are classified as class 1 or class 2
errors. Class 1 errors must be reset manually by pressing the I/O key. Class 2 errors are
reset automatically.
7.1 Overview of class 1 errors & error codes (safety-relevant)
Class 1 errors are indicated by the operating state and error code(s) blinking alternately.
The error codes (see table) enable you to identify errors as either component errors or external
errors (relating to building installations). The first thing is to remove the cause of the error.
Possible causes are described in the following. External errors only occur when the system
requirements of our products are not met. Note: as a rule, error codes “TL”, “TP”, “ST” and “RE
Er1” usually indicate external errors.
Note: Do not pull the plug in the event of an error, since this would interrupt the internal
safety functions midway! Only pull the plug before performing work on the appliance.
Class 1 errors always trigger the following safety function:
The appliance switches to “G OFF” or “Stand By”, and the fire gradually goes out. Any
automatic operation is broken off.
The error code and the message “G OFF” or “stand-by dot” blink alternately.
After the error has been corrected the appliance must be restarted using the I/O key.
Restart/ Reset after class 1 errors is only possible if the cause of the error has been
removed! In the event of error code “ST” you also have to release the temperature cutoff
STB.
Press the I/O key once for every error (“Reset” = error acknowledgement), for ex. in the
event of 2 errors press the I/O key twice.
Class 1
error code Cause of error Desired
values How to correct error
TL HI =
Temperature at air flow
sensor in suction pipe
too high
or
TL Grd =
Temperature rise TL
greater than 40 °C in 120
seconds (gradient).
Measuring point: in
suction pipe [unheated
resistor (see arrow) of air
flow sensor]
Photo of foul sensor
External error (
installation or
operating error). Caused by flow
reversal in suction pipe.
The air flow sensor has heated up
beyond the permissible limit. A TL
error is also triggered when
temperature rises too fast, as this also
points to flow reversal in the suction
pipe.
Possible causes include negative
pressure due to ventilation system,
exhauster hood or lack of chimney
draught or wind pressure via vent pipe
(if there is no chimney) or power
failure (fan). This error is usually
associated with a foul air flow sensor –
see picture. If, contrary to the
requirements, there is no chimney, this
can also occur in the event of a storm
with power failure when the wind
blows directly into the vent pipe.
TL < 85 °C
or
TL rises by no
more than 40
°C per 120 s
Note:
When flue gas
fan is motionless
in stand-by
mode, heat
radiation from
heated resistor
can cause TL to
rise above room
or appliance
temperature. For
this reason error
code TL HI is
inactive in
standby mode.
This is no hardware error!
Let appliance cool off or
wait until TL is no longer
rising and lower than
desired value.
Search for and correct
external cause. Only then do
manual reset via I/O key.
Note: If the temperature of the
air flow sensor rises to values
> 120 °C as a result of flue
gas flow reversal, this is
interpreted as a component
error, and the message LM
Er1 appears in the display
(see below). If the sensor is
still in good order, this error
can be reset after
temperature has returned to
the permissible range.
30

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Wodtke Frank Airplus S4 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Wodtke Frank Airplus S4

Wodtke Frank Airplus S4 Bedienungsanleitung - Deutsch - 76 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info