Commissioning
6720813171 (2016/05)40
10.2.4 Checking the flue gas connection
Check the following points:
Has the prescribed flue gas system been used ( section 8.4 “Flue
gas connection”, page 23)?
Have the configuration instructions from the relevant flue gas system
installation instructions been observed?
Ensure all flue system connections made correctly. Has the annual
CO
2
and NO
x
, clearance to combustible materials been measured?
Have the permissible maximum length limit values from the flue gas
system installation instructions been observed?
10.2.5 Checking the appliance configuration
The burner must only be put into use with the right injectors
( table 14).
Fig. 83 Checking the gas classification label
10.2.6 Measuring the gas inlet pressure (working pressure)
Open at least 2thermostatic radiator valves. Do not switch on the
boiler.
Push on the control panel to open it ( fig. 68, page 32).
Switch off the power supply to the heating system ( fig. 90).
Fig. 84 Switch off the power supply to the heating system
Close the gas valve in a clockwise direction ( fig. 81, page 39).
Turn the vent key through a quarter rotation to undo the boiler door
lock ( fig. 71, see detailed picture, page 37).
Push the fastener down and open the boiler door ( fig. 71,
page 37).
Open the screw plug on the testing nipple for the gas hook-up
pressure and for purging by 2 turns [1].
Reset the digital pressure gauge to “0”.
Connect the pressure gauge connection tube to the positive port of
the testing nipple [2].
Fig. 85 Measuring the gas supply pressure
Slowly open the gas valve by pushing on the gas valve and turning it
¼ rotation in an anticlockwise direction ( fig. 79, page 39).
The gas valve is open when it is in the vertical position.
Switch on the heating system by pressing the mains switch [1] of the
BC10 basic controller.
Boiler Type of gas supply Gas injector diameter [mm]
GB162-50 Natural gas H Venturi
1)
1) Check the gas classification label on the Venturi.
LPG 3P 5.3
GB162-65 Natural gas H Venturi
LPG 3P
5.3
GB162-80 Natural gas H 8.4
LPG 3P
4.7
GB162-100 Natural gas H 8.4
LPG 3P 4.7
Table 14 Gas injector diameter
NOTICE:
Consult the relevant gas utility company for the type
of gas supply.
Check that the actual gas supply is in accordance with
the type of gas supply specified on the gas
classification label ( fig. 83).
Type of gas
supply
Factory presetting for the gas burner
Natural gas H Delivered ready for operation, adjusted to Wobbe
index 14.1 kWh/m³ (with reference to 15 °C,
1013 mbar), applicable to Wobbe index range 12.7
to 15.2 kWh/m³. Markings on gas classification
label: Configured category: G 20 – 2H.
LPG 3P After adaptation by a Gas Safe registered installer,
the unit can be run on LPG.Markings on gas
classification label: Configured category: G 31 – 3P.
Table 15 Factory presetting for the gas burner
6 720 648 726-083.1TD
Throughout the measuring operation, keep the digital
pressure gauge in the same position (horizontal or
vertical) in which it was reset to “0”.
ON
OFF
6 720 648 726-080.1TD
6 720 648 726-085.1TD
2
1
40

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Worcester-Bosch GB162-80 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Worcester-Bosch GB162-80

Worcester-Bosch GB162-80 Installationsanweisung - Englisch - 12 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info