Commissioning
6720813171 (2016/05)38
Open the heating flow and return isolating valves on the pump group
(open position: parallel to the pipe).
Fig. 75 Opening the isolating valves (here: open position)
Read the pressure from the pressure gauge on the pump group or on
the control panel of the BC10.
The pressure in the heating system, which is measured directly at the
boiler, must be at least equal to the required pre-pressure of the
expansion vessel plus 0.5 bar. This minimum pressure must not be less
than 1.0 bar (if the heating system is cold). The maximum pressure in
the heating system, measured directly at the boiler, must not exceed
3.5 bar.
Fig. 76 Reading the pressure gauge
Purge the heating system via the air vents on the radiators. Start at
the lowest floor of the premises and then work your way up from floor
to floor.
Fig. 77 Purging the heating system
If the boiler has been in use for approximately one week and the pressure
reading on the display is less than 1.0 bar, the system has to be topped
up.
The pressure loss in a heating system is caused by air bubbles escaping
via fittings and (automatic) air vent units. The oxygen contained in the
fresh heating water will also escape from the heating water after some
time and cause the pressure in the heating system to drop.
This explains why it is normal that the heating system must be topped up
a couple of times after commissioning it. Eventually the system will have
to be topped up on average once a year.
Should it be necessary to top up the heating system more frequently,
water is probably escaping due to a leakage in the system or a defective
expansion vessel. In this case the cause of the water loss must be
repaired as soon as possible.
10.1.2 Filling the condensate trap with water
Fill the condensate trap with water.
Fig. 78 Filling the condensate trap with water
10.2 Testing and measuring
10.2.1 Checking for gas leaks
Prior to the initial start-up check that the gas supply pipework is gas-
tight; this must be confirmed in the commissioning log book.
6 720 648 726-075.1TD
P1
0
1
6 720 648 726-076.1TD
6 720 648 726-077.1TD
DANGER: Danger of fatal accident from explosive
fumes.
Pipes and fittings may leak after commissioning and
maintenance activities have been carried out.
Carry out a correct leakage test.
Only use approved leak detection spray to locate
leaks.
CAUTION: Damage to the installation due to short
circuits
Cover any hazardous locations prior to locating the
leaks.
Do not spray the leak detection product on cable
runs, plugs or electrical wiring. Do not let it drip onto
them either.
6 720 648 726-016.1TD
38

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Worcester-Bosch GB162-80 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Worcester-Bosch GB162-80

Worcester-Bosch GB162-80 Installationsanweisung - Englisch - 12 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info