Programmable room thermostat settings
Comfort II– 6720810965 (2014/07)
5.2 Installer
These functions are only used by the installer/service engineer
and are useful during both installation of the Comfort II RF to
make adjustment to suit the heating system; during an annual
service/inspection, or to assist with fault finding.
Press the menu button and return button for more than three
seconds to enter the Installer setting area of the programmer.
Six icons are shown across the top of the display:
1. Heating (CH)
2. Hot Water (HW)
3. Holiday
4. Info
5. Settings
6. Installer setting
Selections 1 to 5 are the same as the Timer / programmer user
menu, section 5.1.
Turn the knob to select the Installer icon and press the
knob to enter the function.
Fig. 15 Installer menu
Installer settings menu options
1. System data
2. Reset all
3. Heat circuit
4. Maintenance
5. System info
6. Radio settings
The menu options are displayed on the top line with flashing left
and right arrows heads, indicating that there are other menu
options available. Turning the knob will select each option in
turn, eventually returning to the first option.
1. System data
Turn the knob to select System data
Press the knob to enter System data and HC assignment
is displayed
The display show the number 1
This indicates that there is only one heat circuit
Press the Return button to go back to System data
2. Reset all
The Programmer Installer menus will be reset to factory default
settings, any default settings are described at the beginning of
the functional descriptions.
Turn the knob to select Reset all
▶Press the knob and NO flashes
Turn the knob to select NO or YES
Press the knob to confirm, if YES is chosen all menus within
the Installer menu are reset back to default settings, four
dashes progress across the display until the reset has taken
place,
if NO is chosen, no reset takes place
3. Heat circuit
This function allows the Installer/Service engineer to set the
maximum flow temperature for the central heating circuit to
potentially increase the efficiency of the heating system, the
default value is 85 °C.
Turn the knob to select Heat circuit
Press the knob to display Max flow in °C
Press the knob and the temperature flashes
Turn the knob to set the desired temperature for your
system design requirements
Press the knob to confirm
Press the Return button to go back to Heat circuit
3. Maintenance
a. Fault history
–Boiler faults
–Cont. faults
b. Landlord func.
Maint. date
Maint. contact
a. Fault history
▶Press the knob and Boiler. faults is displayed.
Boiler faults are displayed here and at the boiler, the
Programmable Room thermostat may be located remotely
from the boiler, so viewing the boiler faults at the
Programmable Room thermostat may be useful
06:30 08:30 16:30 22:30
CH 1st 2nd 3rd 4th
CH TEMP 20 °C 16 °C 21 °C 10 °C
DHW ON OFF ON OFF
6720810965-17.1Wo
23456
1
pmam
14

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Worcester-Bosch Greenstar Comfort II RF - 2014-2022 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info