Fault finding and diagnosis
Greenstar Danesmoor Utility 2022+ and Utility System 2022+ - 6 721 846 263 (2022/01) 59
8.5.4 Flame sensing photocell 12/18 models
To check the correct functioning of the photocell, perform the following
actions:
Electrically isolate the burner
Remove the photocell
Connect a voltmeter across the blue and brown wires to the photocell
Reconnect the power to the burner and wait until the burner locks out
due to the false flame fault (red and green LEDs blinking)
Cover the photocell to exclude any light and the voltmeter should
read 3.8 Volts or higher
Expose the photocell to light and the voltmeter should read
approximately 1.2Volts
If these two conditions are not met, change the photocell
Disconnect the voltmeter
Disconnect the burner and replace the photocell
8.5.5 Flame sensing photocell 18/25 and 25/32 models
If the photocell is suspected to be faulty, replace the photocell.
8.6 Oil supply vacuum testing
A vacuum gauge can be attached to the oil pump vacuum test port [1]
and the boiler operated to check the vacuum readings. Oil pumps can
operate if readings are between plus 0.4 bar and minus 0.35 bar.
This means oil tanks can be 4 metres higher (to top of oil) or 3.5 metres
lower (if fitted with a de-aerator or two-pipe oil delivery system) than the
oil pump.
If vacuum is greater than minus 0.35 bar then you must also check that
the oil supply is not obstructed and that the oil supply pipe is correctly
sized.
Accessory 8-716-116-333-0 is available to assist in connecting a
vacuum gauge to the vacuum test port.
Fig. 92 Oil pump ports/connections
[1] Vacuum gauge port
[2] Pressure adjuster
[3] Bleed and pressure gauge port
[4] Return connection
[5] Inlet connection
[6] Auxiliary pressure gauge port
8.7 Air pressure switch and flue overheat reset
This is a blocking error that must be reset by pressing thermostat reset
button or air pressure switch reset button.
If the flue-gas temperature exceeds the cut-off point or the flue is
restricted, the appliance will lockout indicated by code E9 210 [1]
Press the flue-gas thermostat reset button [3], located on the
underside of the support bracket [2].
-or-
Press the air pressure reset button [4], located on the underside of
the support bracket [2].
Fig. 93
[1] Air pressure switch reset
[2] Boiler cross brace
8.8 Air pressure switch connections
Fig. 94 Sensing tube connections
[1] Air pressure switch
[2] Air intake connection (front connection)
[3] Flue exhaust connection (rear connection marked with a +)
6720809437-33.2Wo
3
1
2
6
5 4
NOTICE: APS pressure sensing tubes
Ensure that the pressure sensing tubes are not
kinked or trapped when working on the boiler.
Kinked or trapped tubes will prevent the APS from
functioning correctly
Air pressure switch sensing tube connections:
Ensure that the sensing tubes are connected
correctly, refer to figure 94
6720821686-09.1Wo
2
1
3
21
821683-1.1Wo
59

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Worcester-Bosch Greenstar Danesmoor Utility Regular - Utility System wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info