Possible applications for the Voice Canceller are obvious: you can very simply
stage background music for Karaoke events. Of course, you can also do this at
home or at your rehearsal room before you hit the stage. Singers with their own
band can practice singing dicult parts using a complete playback from a tape
player or a CD, thus minimizing rehearsal time.
2.3.8 CD/Tape input, CD/tape output
X2442USB
Fig. 2.15: 2-track connectors and lamp socket
CD/TAPE INPUT
The CD/TAPE INPUT jacks (RCA) are designed to accept a 2-track recorder
(e.g.DAT recorder), or they can be used as stereo line input. The output signal of
a second XENYX or the BEHRINGER ULTRALINK PRO MX882 can also be connected
here. If you connect the output of a hi- amplier (with a source selection switch)
to the CD/TAPE INPUT, you can easily listen to additional sources (e.g. cassette
recorder, MDplayer, sound card, etc.).
Using the voice canceller function (X1832USB only), you can process all signals
being brought into your mixing console via these connectors.
CD/TAPE OUTPUT
These connectors are wired in parallel to the MAIN OUT and carry the main mix
signal (unbalanced). Connect this to the inputs of your recording device. The nal
output level can be adjusted via the high-precision MAIN MIX fader.
If you connect a compressor or a noise gate post 2-track output,
the main mix fader will probably not be able to create a satisfactory
fade-out effect.
2.3.9 Lamp socket (X2442USB only)
Use this BNC socket to connect a gooseneck lamp (12 V DC, max. 0.5 A).
2.3.10 Level meter and monitoring
X2442USB
Fig. 2.16: Control room and phones sections of the X2442USB
CD/TAPE
The CD/TAPE switch routes the signal from the CD/TAPE INPUT jacks to the level
meter, the CONTROL ROOM OUT outputs and the PHONES jack—this is a simple
way to check recorded signals via monitor speakers or headphones.
SUB 1-2 or SUB
The SUB 1-2 switch routes subgroup 1-2 to the level meter, CONTROL ROOM OUT
and phones.
SUB 3-4
The SUB 3-4 switch performs a similar function for subgroup 3-4
(X2442USBonly).
MAIN MIX
The MAIN MIX switch sends the main mix to the CONTROL ROOM OUT and the
PHONES output as well as to the level meter.
PHONES/CTRL ROOM
Use this control to adjust the control room output level and the
headphonesvolume.
CD/TAPE TO MAIN
When the CD/TAPE TO MAIN switch is depressed, the 2-track input is routed to
the main mix and thus serves as an additional input for tape machines. Youcan
also connect MIDI instruments or other signals here that do not require any
further processing. At the same time, this switch disables the main mix to tape
output link.
POWER
The blue POWER LED indicates that the device is switched on.
+48 V
The red “+48 V” LED lights up when phantom power is switched on.
Phantompower is required to operate condenser microphones.
While phantom power is switched on, do not connect or disconnect
microphones on the mixer (or the stagebox/wallbox). Connect any
micro-phones before switching on phantom power. Additionally,
monitor/PA speakers should be muted before you activate the phantom
power supply. After switching on, wait approx. one minute before
adjusting the input gain so that the system has time to stabilize.
2.3.11 Level Meter
The high-precision level meters always give you an accurate display of
signallevel.
LEVEL SETTING:
When recording to digital recorders, the recorders meter should not go into
overload. This is because, unlike analog recordings, it takes only slightly excessive
levels to create unpleasant digital distortion.
When recording to analog, the VU meters of the recording machine should reach
approx. +3 dB with low-frequency signals (e.g. kick drum). Due to their inertia,
VU meters tend to display too low a signal level at frequencies above 1 kHz.
Youshould only drive instruments such as a Hi-Hat as far as -10dB. Snaredrums
should be driven to approx. 0 dB.
The peak meters of your XENYX display level almost independent of
frequency. A recording level of 0 dB is recommended for all types
of signal.
MODE
The MODE switch determines whether the channels’ SOLO switch operates as PFL
(Pre Fader Listen) or as solo (Solo In Place).
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Xenyx X1832USB xenyx x1832usb wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info