517056
292
Zoom out
Zoom in
Vorherige Seite
1/317
Nächste Seite
MIDI-Datenformat 279
02R96—Bedienungsanleitung
MIDI-Datenformat
1. CHANNEL MESSAGE
2. SYSTEM COMMON MESSAGE
3. SYSTEM REALTIME MESSAGE
Received only when the Automix TIME REFERENCE setting is
MIDI CLOCK.
4. EXCLUSIVE MESSAGE
4.1 Real Time System Exclusive
4.2 System Exclusive Message
4.2.1 Bulk Dump
The following data types of bulk dump are used on the 02R96.
4.2.2 PARAMETER CHANGE
The following data types of parameter change are used by the 02R96.
** tx means that the data can be transmitted from the 02R96. rx means that
the data can be received by the 02R96.
Format Details
1. NOTE OFF (8n)
Reception
Received when the [Rx CH] matches.
Used to control effects.
2. NOTE ON (9n)
Reception
Received when the [Rx CH] matches.
Used to control effects.
3. CONTROL CHANGE (Bn)
Reception
Received when [Control Change Rx] is ON and the [Rx CH] matches.
However if [OMNI] is ON, this is received regardless of the channel. If
[Control Change ECHO] is ON, these messages are echoed to MIDI OUT.
If [TABLE] is selected, parameters will be controlled according to the set-
tings of the [Control assign table]. The parameters that can be set are de-
fined in the CONTROL CHANGE ASSIGN PARAMETER LIST. If
[NRPN] is selected, four messages are used to control the defined param-
eter: NRPN control numbers (62h, 63h) and DATA ENTRY control num-
bers (06h, 26h). Parameter settings are defined in the CONTROL
CHANGE ASSIGN PARAMETER LIST.
Transmission
If [TABLE] is selected, operating the parameters specified in the [Control
assign table] will cause these messages to be transmitted on the [Tx CH] if
[Control Change TX] is ON. The parameters that can be specified are de-
fined in the CONTROL CHANGE ASSIGN PARAMETER LIST.
If [NRPN] is selected, operating the specified parameters will cause data to
be transmitted on the [Tx CH] if [Control Change TX] is ON, using four
messages: NRPN control numbers (62h, 63h) and DATA ENTRY control
numbers (06h, 26h). Parameter settings are defined in the CONTROL
CHANGE ASSIGN PARAMETER LIST.
Command rx/tx function
8n NOTE OFF rx Control the internal effects
9n NOTE ON rx Control the internal effects
Bn CONTROL CHANGE rx/tx Control parameters
Cn PROGRAM CHANGE rx/tx Switch scene memories
Command rx/tx function
F1 MIDI TIME CODE QUARTER
FRAME
rx Used when TIME REFERENCE is
MIDI CLOCK.
F2 SONG POSITION POINTER rx Used when TIME REFERENCE is
MIDI CLOCK.
Command rx/tx function
F8 TIMING CLOCK rx MIDI clock
FA START rx* Start automix (from the
beginning)
FB CONTINUE rx* Start automix (from the
middle)
FC STOP rx* Stop automix
FE ACTIVE SENSING rx Check MIDI cable connections
FF RESET rx Clear running status
Command rx/tx function
F0 7F dd 06 MMC COMMAND tx MMC command (refer to
MMC specication)
F0 7F dd 07 MMC RESPONSE rx MMC response (refer to MMC
specication)
F0 7F dd 01 MIDI TIME CODE rx Used when TIME REFERENCE is
MTC.
Command rx/tx function
F0 43 0n 7E BULK DUMP DATA rx/tx BULK DUMP DATA
F0 43 2n 7E BULK DUMP REQUEST rx/tx BULK DUMP REQUEST
Data name tx/rx function
'm' tx/rx Scene Memory & Request
'S' tx/rx Setup Memory & Request
'a' tx/rx Automix data & Request
'R' tx/rx Input patch library & Request
'O' tx/rx Output patch library & Request
'H' tx/rx Channel library & Request
'G' tx/rx Gate library & Request
'Y' tx/rx Compressor library & Request
'Q' tx/rx Equalizer library & Request
'E' tx/rx Effect library & Request
'J' tx/rx Bus to Stereo library & Request
'K' tx/rx Surround Monitor library & Request
'P' tx/rx Program change table & Request
'C' tx/rx Control change table & Request
'L' tx/rx User dene layer & Request
'I' tx/rx Plug-in User dene & Request
'V' tx/rx User dene key & Request
'N' tx/rx Plug-in Effect Card Data & Request
Command rx/tx function
F0 43 1n 3E 0B PARAMETER
CHANGE
rx/tx 02R96-specic parameter
change
F0 43 3n 3E 0B PARAMETER
REQUEST
rx/tx 02R96-specic parameter
request
F0 43 1n 3E 7F PARAMETER
CHANGE
rx/tx General purpose digital mixer
parameter change
F0 43 3n 3E 7F PARAMETER
REQUEST
rx/tx General purpose digital mixer
parameter request
Type tx/rx function
1 tx/rx Edit buffer
2 tx/rx Patch data
3 tx/rx Setup data
4 tx/rx Backup data
16 tx/rx Function (recall, store, title)
17 rx Function (pair)
18 rx Function (event)
32 rx Key remote
33 tx/rx remote meter
34 tx/rx remote counter
STATUS 1000nnnn 8n
Note off message
DATA 0nnnnnnn nn
Note number
0vvvvvvv vv
Velocity (ignored)
STATUS 1001nnnn 9n
Note on message
DATA 0nnnnnnn nn
Note number
0vvvvvvv vv
Velocity (1-127:on, 0:off)
292

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Yamaha 02R96 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Yamaha 02R96

Yamaha 02R96 Bedienungsanleitung - Französisch - 313 seiten

Yamaha 02R96 Bedienungsanleitung - Italienisch - 316 seiten

Yamaha 02R96 Bedienungsanleitung - Portugiesisch - 288 seiten

Yamaha 02R96 Bedienungsanleitung - Spanisch - 316 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info