About MIDI
183
Owner’s Manual
Basic Structure
Release Time (Control #072)
Messages which adjust the AEG release time set for each
Part.
The value set here is an offset value which will be added to or
subtracted from the voice data.
Attack Time (Control #073)
Messages which adjust the AEG attack time set for each Part.
The value set here is an offset value which will be added to or
subtracted from the voice data.
Brightness (Control #074)
Messages which adjust the filter cutoff frequency set for each
Part.
The value set here is an offset value which will be added to or
subtracted from the voice data. Lower values result in a softer
sound.
Depending on the voice, the effective range may be narrower
than the range available for adjustment.
Decay Time (Control #075)
Messages which adjust the AEG decay time set for each Part.
The value set here is an offset value which will be added to or
subtracted from the voice data.
Effect1 Depth (Reverb Send Level) (Control #091)
Messages which adjust the send level for the Reverb effect.
Effect3 Depth (Chorus Send Level) (Control #093)
Messages which adjust the send level for the Chorus effect.
Data Increment (Control #096)
Decrement (Control #097) for RPN
Messages which increase or decrease the MSB value of pitch
bend sensitivity, fine tune, or coarse tune in steps of 1. You will
need to assign one of those parameters using the RPN in the
external device in advance. The data byte is ignored. When
the maximum value or minimum value is reached, the value
will not be incremented or decremented further. (Incrementing
the fine tune will not cause the coarse tune to be
incremented.)
NRPN (Non-Registered Parameter Number)
LSB (Control #098) (Plug-in Board only)
NRPN (Non-Registered Parameter Number)
MSB (Control #099) (Plug-in Board only)
Messages which adjust a voice’s vibrato, filter, EG, drum
setup or other parameter settings.
First send the NRPN MSB and NRPN LSB to specify the
parameter which is to be controlled. Then use Data Entry
(page 182) to set the value of the specified parameter.
Note that once the NRPN has been set for a channel,
subsequent data entry will be recognized as the same
NRPN’s value change. Therefore, after you use the NRPN, you
should set a Null (7FH, 7FH) value to avoid unexpected
results.
For details, refer to the owner’s manual of the relevant Plug-in
Board.
RPN (Registered Parameter Number) LSB (Control #100)
RPN (Registered Parameter Number) MSB (Control #101)
Messages which offset, or add or subtract values from a
Part’s pitch bend sensitivity, tuning, or other parameter
settings. First send the RPN MSB and RPN LSB to specify the
parameter which is to be controlled. Then use Data
Increment/Decrement (page 183) to set the value of the
specified parameter. Note that once the RPN has been set for
a channel, subsequent data entry will be recognized as the
same RPN’s value change. Therefore after you use the RPN,
you should set a Null (7FH, 7FH) value to avoid unexpected
results.
The following RPN numbers can be received.
Channel Mode Messages
The following Channel Mode Messages can be received.
All Sounds Off (Control #120)
Clears all sounds currently sounding on the specified
channel. However, the status of channel messages such as
Note On and Hold On is maintained.
Reset All Controllers (Control #121)
The values of the following controllers will be reset to the
defaults.
All Notes Off (Control #123)
Clears all notes currently on for the specified channel.
However, if Hold1 or Sostenuto is on, notes will continue
sounding until these are turned off.
RPN MSB RPN LSB PARAMETER
00 00 Pitch Bend Sensitivity
00 01 Fine Tune
00 02 Coarse Tune
7F 7F Null
2nd BYTE 3rd BYTE MESSAGE
120 0 All Sounds Off
121 0 Reset All Controllers
123 0 All Notes Off
126 0 - 16 Mono
127 0 Poly
CONTROLLER VALUE
Pitch Bend Change 0 (center)
Aftertouch 0 (off)
Polyphonic
Aftertouch 0 (off)
Modulation 0 (off)
Expression 127 (max)
Hold1 0 (off)
Portamento 0 (off)
Sostenuto 0 (off)
Soft Pedal 0 (off)
Portamento Control Cancels the Portamento source key number
RPN Number not specified; internal data will not change
NRPN Number not specified; internal data will not change
183

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Yamaha MOTIF ES7 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Yamaha MOTIF ES7

Yamaha MOTIF ES7 Installationsanweisung - Deutsch - 35 seiten

Yamaha MOTIF ES7 Bedienungsanleitung - Deutsch - 300 seiten

Yamaha MOTIF ES7 Installationsanweisung - Englisch - 35 seiten

Yamaha MOTIF ES7 Bedienungsanleitung - Holländisch - 300 seiten

Yamaha MOTIF ES7 Bedienungsanleitung - Französisch - 300 seiten

Yamaha MOTIF ES7 Installationsanweisung - Französisch - 35 seiten

Yamaha MOTIF ES7 Bedienungsanleitung - Italienisch - 308 seiten

Yamaha MOTIF ES7 Installationsanweisung - Italienisch - 12 seiten

Yamaha MOTIF ES7 Bedienungsanleitung - Portugiesisch - 300 seiten

Yamaha MOTIF ES7 Bedienungsanleitung - Spanisch - 297 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info