Climate for an ambient
classification temperature of
SN +10 to +32 °C
N +16 to +32 °C
ST +18 to +38 °C
T +18 to +43 °C
Electrical connection
Before plugging in, ensure that the voltage and frequency
shown on the serial number plate correspond to your
domestic power supply.
Voltage can vary by ±6% of the rated voltage.
For operation with different voltages, a suitably sized auto-
transformer must be used.
Important
The appliance must be earthed.
The power supply cable plug is provided with a contact for
this purpose.
If the domestic power supply socket is not earthed. con-
nect the appliance to a separate earth in compliance with
current regulations, consulting a specialist technician.
The Manufacturer declines all responsibility if the
above safety precautions are not observed.
This appliance complies with the following
E.E.C.
Directives:
- 87/308 EEC of 2/6/87 relative to radio interference
suppression.
- 73/23 EEC of 19.2.73 (Low Voltage Directive) and
subsequent modifications.
- 89/336 EEC of 3.5.89 (Electromagnetic
Compatibility Directive) and subsequent modifica-
tions.
Installation
Take utmost care when handling your appliance
so as not to cause any damages to the cooling
unit with consequent possible fluid leakages.
During normal operation, the condenser and compres-
sor at the back of the appliance heat up considerably.
Always ensure that there is adequate ventilation as a fail-
ure to do this will result in component failure and possi-
ble food loss. See installation instructions.
Important: if the supply cord is damaged, it must be
replaced by a special cord or assembly available from
the manufacturer or its service agent.
Positioning
Unpack the cabinet and check that it is in good condi-
tion and free of any transport damage.
The appliance must not be located close to radiators or
gas cookers.
Avoid prolonged exposure of the appliance to direct
sunlight.
For safety reasons, minimum ventilation must be as
shown in Fig.
Attention: keep ventilation openings clear of obstruc-
tion.
It is necessary that the niche is provided with a conduct
of venti-lation having the following dimensions:
Depth: 50 mm
Width: 540 mm
The climate classification can be found on the rating plate,
which is located inside the cabinet on the left hand wall.
The following table shows which ambient temperature is
correct for each climate classification:
41