protection fuse rating is marked on the rear panel.
The on/off switch is positioned on the rear panel
to prevent accidental operation.
2 Network port RJ45 socket for connection to
an Ethernet network or PC using UTP CAT5 cable.
This port is recommended for configuring the
system with iDR software. The MDI/X switch
selects network or direct to PC operation. The link
LED lights when communication is established.
The TX LED lights when data is communicated.
Note: The RS232, MIDI, SysNet and PL-Anet
control ports are not all available at the same time.
A combination of two is selected using iDR
System Manager. The associated active LED
lights when the port is available.
3 RS232 (MODEM) port This is used for
connection to a modem so that the unit can be
interrogated by a remote PC over a standard
telephone line. It can also be used for system
configuration using iDR System Manager software
but the faster network port is recommended.
Pressing the front panel switch selects either the
front or rear RS232 port.
4 MIDI port Standard opto-isolated MIDI port
with IN, THRU and OUT connectors.
5 SysNet port An RS232 serial port for
communication with third party remote controllers
running the Allen & Heath SysNet protocol.
6 PL-Anet port An RS485 serial port for
communication with a network of Allen & Heath
PL wall plates and remote controllers using CAT5
STP cable.
7 DR-Link port RJ45 socket for control of iDR
audio and logic expander units using CAT5 STP
cable. IN and OUT ports are provided on the
expander units so that the control can be daisy
chained through a system with more than one
expander.
8 Audio expander ports RJ45 sockets for
communicating 8 channel digital audio between
the iDR-8 and its expanders using CAT5 STP
cable. Two cables are required between the
expander and iDR-8, one for the audio, the other
for DR-Link control.
9 Mic/Line inputs Balanced XLR inputs for
microphone and line level sources. Adding the
iDR-in expands the iDR-8 to 16 inputs.
10 Audio outputs Balanced XLR line level
outputs with maximum +18dBu level. Adding the
iDR-out expands the iDR-8 to 16 outputs.
11 Monitor inputs and outputs Balanced TRS
jacks for L and R monitor inputs and outputs.
These provide a line level version of the front
panel stereo headphones output and can daisy
chain through multiple iDR units.
12 Switch closure inputs These are provided
on the iDR-switch. They can be hard wired from
remote wall plate and controller switches and
relays.
13 Open collector logic outputs These are
provided on the iDR-switch. They can be used to
control LEDs, lamps, relays and other devices.
14 Earth terminals These are provided to earth
(ground) the switch and logic output cable
shields.
Use null-modem cable to connect to PC com port
CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN.
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.
ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.
THIS APPARATUS MUST BE EARTHED.
WARNING
47-63Hz ~ 90W MAX
100 - 240V~
active
RS232 (MODEM)
Complies with UL6500, CSA-E65, EN60065
MONITOR OUT
LINKTX
Refer to user guide for port selection details
FUSE: T1.6AL
AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
SERIAL NUMBER
Made in the UK by ALLEN&HEATH LIMITED
MONITOR IN
DIGITAL EXPANDER
R
PL-ANET
DR-LINK
LR
AUDIO OUTAUDIO IN
THRU
active
MDI/X
NETWORK
MIDI OUT
active
MIDI IN
active
SYSNET PORT
L
OUT 8OUT 7OUT 5
LINE OUTPUTS
OUT 6OUT 4
IN 8IN 7IN 5
MIC/LINE INPUTS
IN 6IN 4
OUT 3OUT 2OUT 1
IN 3IN 2IN 1
Made in the UK by ALLEN&HEATH LIMITED
AUDIO OUT
CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN.
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.
ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.
47-63Hz ~ 25W MAX
100 - 240V~
THIS APPARATUS MUST BE EARTHED.
WARNING
SERIAL NUMBER
AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
FUSE: T500mAL
next
OUT
DR-LINK
previous
IN
IN 10
Complies with UL6500, CSA-E65, EN60065
IN 16IN 15
MIC/LINE INPUTS
IN 14IN 13IN 11IN 12
IN 9
AUDIO IN
Made in the UK by ALLEN&HEATH LIMITEDCAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN.
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.
ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.
THIS APPARATUS MUST BE EARTHED.
WARNING
47-63Hz ~ 25W MAX
100 - 240V~
SERIAL NUMBER
FUSE: T500mAL
AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
next
OUTDR-LINK
previous
IN
OUT 10
Complies with UL6500, CSA-E65, EN60065
OUT 16OUT 15
LINE OUTPUTS
OUT 14OUT 13OUT 11OUT 12OUT 9
VG
G4321G5678G1211109G13141516G20191817G21222324
SWITCH INPUTS
LOGIC OUTPUTS
123
+-
4
VGVGVG+-+-+-
567
+-
8
+-+-+-
910
+-+-+-+-
11
1214
+-+-+-+-
151613
switch
G
opto
+10V
2K2
opto
+
-
V
G
+10V DC max total 500mA
open collector
+24V DC, 200mA max
+10V
FUSE: T500mAL
WARNING
THIS APPARATUS MUST BE EARTHED.
ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.
100 - 240V~
47-63Hz ~ 15W MAX
CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN.AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.Made in the UK by ALLEN&HEATH LIMITEDComplies with UL6500, CSA-E65, EN60065
Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.
Art des Missbrauchs:
Forenregeln
Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:
Lesen Sie zuerst die Anleitung;
Schauen Sie nach, ob die Frage bereits gestellt wurde;
Stellen Sie die Frage so deutlich wie nur einigermaßen möglich;
Erwähnen Sie was Sie bereits versucht haben um das Problem zu lösen;
Ist Ihr Problem von einem Besucher gelöst dann lassen Sie ihn / sie wissen in diesem Forum;
Falls Sie reagieren möchten, so verwenden Sie bitte das Antworten- Formular;
Da ihre Frage für alle Besucher sichtbar ist, sollten Sie lieber keine persönliche Daten erwähnen.
Neu registrieren
Registrieren auf E - Mails für Allen-Heath iDR-8 wenn:
neue Frage gestellt werden
neue Handbücher vorhanden sind
Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.
Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.
Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.
Ihre Frage wurde zu diesem Forum hinzugefügt
Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.