702694
7
Zoom out
Zoom in
Vorherige Seite
1/20
Nächste Seite
7
PROGRAMMING THE QUIK BRIDGE
®
Table 7 displays the 17 locations that can be programmed on the Quik
Bridge
®
.
Table 7: Quik Bridge
®
output locations and segments
0 1-4 Programming code
1 1 Output 1 event
2 Output 1 time
2 1 Output 1 Transmitter selection
2 Output 1 Special Setting
3 1 Output 2 event
2 Output 2 Time
4 1 Output 2 Transmitter selection
2 Output 2 Special Setting
5 1 Output 3 event
2 Output 3 time
6 1 Output 3 Transmitter selection
2 Output 3 Special Setting
7 1 Output 4 event
2 Output 4 time
8 1 Output 4 Transmitter selection
2 Output 4 Special Setting
9 1 Output 5 event
2 Output 5 time
10 1 Output 5 Transmitter selection
2 Output 5 Special Setting
11 1 Output 6 event
2 Output 6 time
12 1 Output 6 Transmitter selection
2 Output 6 Special Setting
13 1 Output 7 event
2 Output 7 time
14 1 Output 7 Transmitter selection
2 Output 7 Special Setting
15 1 Output 8 event
2 Output 8 time
16 1 Output 8 Transmitter selection
2 Output 8 Special Setting
17 1 On if Quik Bridge
®
tamper is enabled
Output event
Enter the number for the event that you wish to program for the output.
Table 8: Quik Bridge
®
output events
0 Zone Open
1 Zone Tamper
2 TX Low Battery
3 TX Lost
4 TX short supervision fault
5 Clean me fault
6 Zone open or tamper (default value)
7 TX lost or low battery
8 TX lost, low battery or tamper
9 Zone open, TX Lost, low battery or tamper
10 Keyfob disarm
11 Keyfob arm
12 Keyfob arm or disarm
13 Keyfob arm stay
14 Keyfob exit
15 Fob fire
16 Fob Medical
17 Keyfob panic
18 Keyfob aux 1 (Option 4 from ‘Using the 4 button keyfob)
19 Keyfob aux 2 (Option 5 from ‘Using the 4 button keyfob)
20 Receiver Jam
21 Box tamper (receiver or Quik Bridge
®
)
22 Receiver communication trouble
23 Receiver communication trouble, box tamper or jam
24 Reserved
25 Reserved
Output time
This can be set from 0-255 in minutes or seconds. The unit is set in the
Special Setting segment.
Special Setting
This can be set in the different bits of the segment.
Bit 1: selection of time in seconds or minutes.
Turn bit 1 on to time the output in minutes.
Turn bit 1 off to time the output in seconds.
Bit 2: selection of inverted output.
Turn bit 2 on to invert output activation.
Turn bit 2 off for normal output activation.
Important: After the walk test mode times out, the detector returns to
normal operating mode. In normal operating mode, the wireless PIR only
supervises every 2 minutes and the LED is disabled to reduce battery
consumption.
Transmitter Selection
Each bit of the segment corresponds with an output that should be
activated. Each transmitter can be set to activate 1, several or every out-
put. Turn the corresponding bit of the segment on if the transmitter should
activate the output.
Table 8: Quik Bridge
®
output events
CONNECTING THE QUIK BRIDGE
®
TO THE PANEL
The Quik Bridge
®
is compatible with any control panel via 8 open collector
outputs. After you have enrolled the transmitters and programmed the Quik
Bridge
®
, you MUST disconnect the CSX75 LCD keypad from the Quik Bridge
®
and the Receiver. You should then connect the Quik Bridge
®
to ensure that
zones 1-8 on the panel are programmed to match the programming of the
outputs on the Quik Bridge
®
.
Connect the Quik Bridge
®
outputs to the zone inputs on the control panel.
There are 4 ways to wire the loop receiver to the control panel. Refer to
Figures J1 through J4 for panel connections.
PROGRAMMING THE PANEL
Please refer to the panel’s instruction manual to see the steps for program-
ming the inputs.
You must ensure that the programming of the panel inputs matches the
programming of the output events on the Quik Bridge
®
. For example there
is no point programming an output event as 5 (Clean me fault), if there is
not an equivalent zone type on the panel.
SPECIFICATIONS
Compatibility: Control panels with hardwire loops.
Housing: RXWEH00
Receiver: RX8W8CA-Pcb
Power Requirements: 10 – 14 VDC
Current Draw: 60 mA maximum
Open Collector Outputs (1-8, B, S):
maximum applied voltage 16 VDC
maximum sink current 50 mA (typical) 15 mA (minimum)
Temperature Range: -10°C to +40°C
Dimensions: 10.31 x 13.13 x 2.5 cm (L x W x H
elpmaxE gnitteS
1tuptuoetavitcaot1rettimsnarttesoT
)1tnemges2noitacol(
-------1
tuptuoetavitcaot8dna2srettimsnarttesoT
)1tnemges4noitacol(2
8-----2-
8tuptuoetavitcaotsrettmsnart8llatesoT
)1tnemges61noitacol(
87654321
noitacoL tnemgeS noitpircseD
ataD tnevE
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Aritech RXW8 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info