7.3 Resistance ranges
No-load voltage: approx. 1.3 V - 3.3 V, max. test current 2.5 mA.
42 MΩ-range, response time approx. 20 s
Measuring range Resolution Accuracy
Accuracy overload
protection
420 Ω 0,1 Ω ± (1.2 % of reading + 8 digits)
600 V
eff
600
V
DC
4,2 kΩ 1 Ω ± (0.9 % of reading + 4 digits)
600 V
eff
600
V
DC
42 kΩ 10 Ω ± (0.9 % of reading + 4 digits)
600 V
eff
600
V
DC
420 kΩ 100 Ω ± (1.2 % of reading + 4 digits)
600 V
eff
600
V
DC
4,2 MΩ 1 kΩ ± (1.2 % of reading + 4 digits)
600 V
eff
600
V
DC
42 MΩ 10 kΩ ± (3.0 % of reading + 8 digits)
600 V
eff
600
V
DC
7.4 Diode testing
The stated measurement accuracy applies in the range between 0.4 V and
0.8 V.
Overload protection for diode testing: 600 V
eff
/ 600 V
DC
Measuring
range
Resolution Accuracy
max. meas.
current
Max. no-load
voltage
0.1 mV
± (1.5 % of reading + 5 digits)
1,5 mA
3,3 V
7.5 Continuity testing
The integrated buzzer sounds at resistances R < 50 Ω.
7.6 AC ranges
(Multimeter with current transducer attachment. Current transducer grips single
live conductor wire).
Measurement accuracy is ± (% of reading + number of digits) at a temperature
of 23 °C ± 5 °C.
Max. current of enclosed current transducer 300 A!
Measuring range
Resolution Output voltage Accuracy
300 A 0.1 A 1 mV/ 0.1 A
± (1.5 % of reading + 5 digits)
in frequency range 40 Hz - 300 Hz
8. Measuring with the BENNING MM 4
8.1 Preparation for measurement
Store and use the BENNING MM 4 only under the correct temperature condi-
tions specified. Always avoid prolonged exposure to sunlight.
- Check nominal voltage and current data on the black safety test lead and red
test probe. The black test lead and the red test probes supplied correspond
to the BENNING MM 4 in nominal voltage and nominal current.
- Check insulation of the safety test lead and red test probe. If the insulation
is damaged, discard the lead and test probes immediately.
- Check the continuity of the safety test lead. If the conductor in the safety
test lead is interrupted, discard the safety test lead immediately.
- Before selecting another function at the sliding switch 2 or function button
4, the safety test lead and red test probes must first be disconnected from
the measurement point.
- Strong sources of interference in the vicinity of the BENNING MM 4 may
cause unstable or incorrect readings.
8.2 Voltage measurement
Always observe the maximum voltage to earth potential!
Electrical hazard!
The maximum voltage which may be applied to the sockets of the Multimeter with
- COM socket 7, marked black,
- V-Ω socket (positive) 8 for voltage and resistance measurements, continu-
ity and diode testing (marked red) of the BENNING MM 4 with reference to
earth potential is 600 V.
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Benning MM 4 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info