you will see the bolt blocking the hole. Move the counterweight slightly
to make it disappear in its drill hole and reveal the hole. If it doesn‘t,
carefully loosen the counterweight screw until the bolt moves. Remove
the safety cover (23, illustration 1d) from the rod. Hold the counter-
weight firmly whilst moving it to about the middle of the counterweight
rod (22, illustration 1d). Tighten the counterweight fastening screw and
then replace the safety cover.
NOTE:
If the counterweight ever slips, the safety cap (23, Fig. 1d) prevents the counter-
weight from sliding entirely off the shaft. Always leave the safety cap in place when
the counterweight is on the shaft.
6. Set the latitude. Setting the latitude is easier if it is set before you attach the
optical tube to the assembly. Locate the latitude dial (28, Fig. 1d); note that
there is a triangular pointer above the dial located on the mount. The pointer
is not fixed; it moves as the mount moves.
Determine the latitude of your observing location. See APPENDIX B:
LATITUDE CHART, page 28-29, for a list of latitudes, or check an atlas.
Move the latitude T-handle screws in order to move the mount until the
pointer points to your latitude. The two T-handle screws (EXOS-2 only) work
in a „push - pull“ operation—as you tighten one, loosen the other. When the
pointer points at your latitude, tighten both screws until they make contact
with the mount. The EXOS-1 has on screw with similar operation.
At your observing site, set up the telescope assembly so that this leg
approximately faces North (or South in the Southern Hemisphere).
7. Attach the cradle assembly to the mount Models R and N: Remove the
optical tube from the cradle and slide the cradle assembly (11, Fig. 1a) onto
the cradle mounting slot. See Fig. 7. The rounded base of the cradle assem-
bly fits into the rounded portion of the mounting slot. Tighten both the cradle
locking knob and the secondary locking knob to a firm feel.
8. Position optical tube – Models AR and NT: Unscrew the cradle ring lock
knobs (13, Fig. 1a) and open the cradle rings. While firmly holding the opti-
cal tube (10, Fig. 1a), position it onto the cradle rings (14, Fig. 1a) with
the mid-point of the optical tube’s length lying roughly in the center of the
cradle ring assembly. Point the tube so that the front end (this end comes
shipped with the dust cover (9, Fig. 1a) over it) is oriented as depicted
in Fig. 1a. Then close the cradle rings (14, Fig. 1a) over the optical tube.
Loosely tighten the cradle ring lock knobs just to hold the tube securely in
place until you balance it. See Balancing the telescope, page 13.
9.
Attach viewfinder bracket
(Abb. 9b). Locate the viewfinder bracket
screws (15, Fig. 1b and Fig. 9a) and remove the nuts from the screws.
Slide the holes in the viewfinder bracket over the viewfinder bracket
screws. Replace the nuts and tighten to a firm feel only.
9a. Attach viewfinder tube:. Back off the viewfinder collimation screws (5,
Fig. 1b) and slide the viewfinder tube into the bracket. Orient the view-
finder eyepiece as depicted in Fig. 1b. Tighten the collimation screws
to a firm feel. See Aligning the viewfinder, page 14.
10. Insert the eyepiece: NT models (Fig. 10a): Lift to remove the dust cap
from the eyepiece holder on the focuser assembly. Set the dust cap
aside in a safe place and replace it when you have finished observing
to protect the eyepiece assembly. Back off the eyepiece thumbscrews
(1, Fig. 1a) and insert the supplied 25mm eyepiece (3, Fig. 1a) into
the the eyepiece holder. Tighten the holder thumbscrews to a firm
feel to secure the eyepiece. AR models (Abb. 10b): Lift to remove the
dust cap from the eyepiece holder on the focuser assembly. Set the
dust cap aside in a safe place and replace it when you have finished
observing to protect the eyepiece assembly. Back off the eyepiece
thumbscrews (1, Fig. 1b) and slide the diagonal prism into the holder
and tighten the thumbscrews to a firm feel only. Insert the supplied
25mm eyepiece (3, Fig. 1b) into the the diagonal prism. Tighten the
prism‘s thumbscrews to a firm feel to secure the eyepiece.
Looking at or near the Sun will cause instant and irreversible damage to your eye! 12
assemblInG exos-2
Fig. 8a: Place the optical tube
in rings and loosely tighten the
cradle ring lock knobs.
Cradle rings
Lock
knobs
Fig. 9b: Viewfinder assembly.
Slide bracket into slot.
Fig. 6a: Attach counterweight
assembly (EXOS-1)
Fig. 7: Mounting the cradle assembly
to the mount shaft (EXOS-2)
Cradle
assembly set
A
B
C
Safety cap
Counter-
weight
shaft
Counterweight
locking knob
Counter-
weight
Shaft base
DEC-setting circle
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bresser Messier Exos 1 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Bresser Messier Exos 1

Bresser Messier Exos 1 Bedienungsanleitung - Deutsch - 48 seiten

Bresser Messier Exos 1 Kurzanleitung - Alle Sprachen - 16 seiten