5 Maintenance
5.3 Cleaning the particle trap
1. Switch off the appliance, Zchapter 4.3, „Switching off“
2. Remove the dust container Zchapter 5.1, „Emptying and cleaning the
dust container“.
3. If dirt is visible in the suction channel (Fig. 13/A1), lay the appliance on
its side.
4. Open the particle trap by twisting it off (Fig. 13/B). The dirt will fall out
of the opening. If necessary, help a bit by hand.
5. Empty the dirt into a dustbin.
6. Close the cleaned suction channel by refitting and fastening the particle
trap.
7. If you haven't done this by now, firmly push the dust container back into
its receptacle. Check that it is securely fitted..
5.4 Cleaning the hygienic exhaust filter
1. Switch off the appliance, Zchapter 4.3, „Switching off“
2. Push the release catch of the exhaust filter cover down (Fig. 14/A) and
fold down the exhaust filter cover.
3. Remove the exhaust filter (Fig. 14/B).
4. Tap the exhaust filter over a dustbin for a rough cleaning. Remove larg-
er agglomerations of dirt by hand.
5. Remove residual dust with a soft brush, e.g. the supplied furniture
brush.
6. Ifthe filter is damaged or deformed, replace it.(ordering information
Zchapter 5.5, „Spare parts and accessories“).
7. Place the clean/new exhaust filter back into its fitting.
8. Attach the exhaust filter cover at the bottom side first and then fold it
upwards.
5.5 Spare parts and accessories
Ordering address: Zpage 48, „International Service“.
Further information: Z www.dirtdevil.de
The following accessories and spare parts can be reordered:
5.6 Before you send in the appliance
Before contacting your authorised Royal dealer, Royal service partner or
appliance market or sending in the appliance, first follow the procedure in
the following table to check if you can solve the problem yourself.
BA
1
13
BA
14
ATTENTION:
Only use original spare parts from the scope of delivery or those that you
have acquired by reordering.
Item number Description
5050001 1 Dual motor protection filter (2 pieces: foam plastic filter
element (Fig. 1/19) and filter holder (Fig. 1/20))
5050002 1 hygienic exhaust filter
5050003 1 particle trap Item number Description
M203 1 parquet brush M219 1 mini turbo brush
M209 1 turbo brush M232 1 long crevice nozzle
WARNING:
Danger of injury! Never use a defective appliance! Always switch off the
appliance and disconnect it from the mains before starting troubleshoot-
ing Zchapter 4.3, „Switching off“.
Problem Solution
The appli-
ance will
not start
The socket does not carry current.
Test the vacuum cleaner at another socket which you are
sure carries current.
Power cord is damaged. Have the power cord replaced by
Royal Appliance Customer Service, address, Zpage 48,
„International Service“.
The vacu-
um cleaner
stops sud-
denly.
The overheating protection has tripped (possibly due to
blocked suction channels, filters, or similar).
Switch the appliance off and pull the plug out of the socket.
Remove the cause of overheating (e. g. by disassembling
telescopic tube and suction hose and removing the obstacle
and/or cleaning filters). Wait for about 45 minutes. After the
appliance has cooled off, you may switch it on again.
Cleaning
indicator
(Fig. 1/13,
optional)
lights up.
The dust container is full.
Empty / clean the dust container, Zchapter 5.1, „Emptying
and cleaning the dust container and Zchapter 5.3, „Clean-
ing the particle trap“
The clean-
ing results
are unsat-
isfactory in
spite of the
appliance
working
correctly.
The bypass vent (Fig. 1/24) is open.
Close the bypass vent (Fig. 1/24).
The attached nozzle is unsuitable.
Change the nozzle Zchapter 3.2, „Selecting the proper noz-
zle“
The position of the "carpet/hard floor" selector (Fig. 1/28) is
unsuitable.
Set the "carpet/hard floor" selector (Fig. 1/28) to the correct
position for the type of floor, Zchapter 4.2, „Vacuum clean-
ing“, step 4.
The dust container is full.
Empty / clean the dust container Zchapter 5.1, „Emptying
and cleaning the dust container“.
The filter is dirty.
Change/clean the respective filter Zchapter 5.2, „Cleaning
the cyclone unit and the dual motor protection filter“ or
Zchapter 5.4, „Cleaning the hygienic exhaust filter“.
Nozzle, telescopic tube or suction hose are blocked.
Remove the obstacle. If necessary, use a long wooden stick
(e.g. a broomstick) to do this.
Problem Solution
Infinity Excell.book Seite 15 Dienstag, 1. März 2011 9:33 09
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Dirt Devil m 5050 infitnity vx 8 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info