INSTALLATION MANUAL
!Tip
When checking whether the main burner continuous to burn, it is possible that it switches off after 15 seconds. In
that case, this will be caused by the fact that there is no ionization detection and because the glass window has
not been placed. This can be regarded as a situation where the main burner continues to burn.
!Caution
Always wait 5 minutes before re-igniting the appliance.
No changes may be made to the gas control.
7.3.2 Main burner
!Caution
The ignition electrode should ignite the main burner within a couple of seconds and without popping.
The main burner(s) must cross the full burner smoothly and without popping and continue to burn.
If the appliance does not ignite after three restarts and enters hard lockout, it may never be reset by
disconnecting it from the power supply. If a restart is necessary after all: remove the glass pane and make sure
the gas is able to escape from the appliance. After this, the appliance may be disconnected from the power
supply for 10 seconds. After these 10 sec., the power supply may be reconnected. Ignite the appliance in the
same way as the first ignition, as indicated in section 7.3.1.
Ø
Check operation of the main burner from a cold condition.
Ø
If sparks are determined between the ignition electrodes, the main burner should burn within a few seconds.
!Tip
The flame picture and a good flame transfer can only be properly judged if the glass window is installed.
Use the malfunction search diagram (Appendix 1) if the ignition of the main burner does not comply with the
above-mentioned requirements.
7.4 Flame picture
The flame picture can only really be assessed when the appliance has been burning for several hours. Volatile
components from paint, materials, etc., which evaporate in the first hours, will affect the flame picture.
Ø
Check whether the flame picture is acceptable.
Ø
Consult the malfunction search diagram (Appendix 1) if the flame picture is not acceptable, in order to solve the
problem.
8. Maintenance
Once per year, the appliance must be checked, cleaned and, if necessary, repaired by a competent installer in the
field of gas heating and electricity. Check at least whether the appliance is working properly and safely.
!Caution
Close the gas tap when performing maintenance work.
Check the gastightness after repair.
Make sure there is no voltage on the appliance.
SS-absolutely do not clean the concentric system (internally) with a steel brush or metal sponge, for example.
This will damage the oxide skin and could lead to leaks in the system as a result of pitting corrosion.
Ø
Clean glass pane(s), if necessary.
!Caution
Only clean a glass pane once it has reached room temperature.
Caution!
Avoid damage to the glass pane(s).
Avoid/remove fingerprints on the glass pane(s), as they will burn into the glass.
Clean the pane(s) as described in the user manual.
Regularly remove accumulated dirt, as it can burn into the glass.
Do not use the appliance when a pane is broken and/or cracked, until it has been replaced as described from
section 5.10.
!Caution
If necessary, place back the wood or pebble set correctly; for this, see from section 5.10.
Ø
Inspect the flue gas discharge system.
!Caution
You must always perform a final inspection.
19
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für DRU Cosmo Tunnel wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von DRU Cosmo Tunnel

DRU Cosmo Tunnel Bedienungsanleitung - Deutsch - 28 seiten

DRU Cosmo Tunnel Installationsanweisung - Deutsch - 40 seiten

DRU Cosmo Tunnel Bedienungsanleitung - Englisch - 28 seiten

DRU Cosmo Tunnel Bedienungsanleitung - Holländisch - 28 seiten

DRU Cosmo Tunnel Installationsanweisung - Holländisch - 40 seiten

DRU Cosmo Tunnel Installationsanweisung - Französisch - 40 seiten

DRU Cosmo Tunnel Bedienungsanleitung - Französisch - 28 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info