571624
16
Zoom out
Zoom in
Vorherige Seite
1/44
Nächste Seite
English
INSTALLATION MANUAL
6. Control
The appliance is supplied with a wireless black remote control for the user (see appendix 3, fig. 35 (B)). As an option,
an orange remote control can be supplied for the installer (see appendix 3, fig. 35 (O). Controlling the flame height,
igniting and switching off take place through the black remote control controlling the receiver. Some fires can also
be controlled in an alternative way. These options are described further down in this chapter.
The user manual describes the operation of the appliance, including the operation of the remote control and
alternative methods of operation.
!Caution
Do not ignite the appliance before the gas, discharge and electric connections have been fully installed, first
observe the procedure described in chapter 7.3.
Chapter 6 of the manual supplied applies to an appliance equipped with the CM system.
6.1 Remote controls
6.1.1 Black remote control for the user
Proceed as follows to make the black remote control ready for use:
Ø
Place the two penlite batteries (AA) in the battery holder of the remote control.
Ø
Make sure the voltage of the atmospheric fire is not switched off for longer than 5 minutes.
Ø
If the remote control does not have the "BND" state, the following operations must be performed: Press the menu
button (button with square symbol) on the remote control for at least 10 seconds and then press a few times until
“BND” appears on the screen with the receiving symbol.
Ø
Press the “arrow up” and “arrow down” buttons briefly and simultaneously, so that a (flashing) warning triangle and
an hourglass appear in the screen as well.
Ø
As soon as logging on is finished, the start screen will appear
!Tip
Ale functions are extensively explained in the supplied user manual.
6.1.2 Orange remote control for the installer
By means of the optionally available orange remote control, it is possible to read all information stored in the
receiver. In this way, the last 20 error messages can be retrieved, and it will also be possible to read how many
times an error occurred. Moreover, this remote control can also be used to adjust the basic settings and to read the
size of the ionization flow. It is also required for a wired Domotics control.
6.2 Alternative control (if applicable)
In addition to the remote control, it is also possible to operate the fire in alternative ways. For this purpose, a
Domotics system can be connected to the receiver. This can be a wired or a wireless system. The various
possibilities are described below (see appendix 3, fig. 35, 36 and 37).
6.2.1 Wired
Wired connection of the Domotics system to the receiver takes place via a 0-3VDC direct current
(see appendix 3, fig. 36 (D)).
!Caution
A higher voltage than 3V will damage the receiver and is therefore not permitted.
Tip!
In case of Domotics systems with an output voltage of 0-10V, you should switch the voltage back to 0-3VDC.
Use a voltage distributor made of resistors. For example, 2200 ohms and 680 ohms. The voltage above 680 ohms
resistance can be used on the input of the 0-3VDC. Low ohmic resistors must be used.
By controlling the height of the voltage, the receiver will be able to calculate the position of the fire. Table “B1” in
appendix 3, fig. 37 shows the relationship between the voltage and the height of the flame. If you have an
appliance with 2 burners, table “B2” will apply. It shows the relationship between the voltage, the height of the
flame and the number of burners.
Proceed as follows when connecting the Domotics system to the receiver:
Ø
Connect the 0-3VDC signal to the connector, to which a black and yellow wire are connected
(see appendix 3, fig. 36 (D)).
Ø
Use the orange remote control to select the option for a wired connection: go to position 8 in the first menu and
select an appliance with single burner (option 2) or an appliance with two burners (option 3). For this, read the
manual of the orange remote control.
16
16

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für DRU Lugo 80 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von DRU Lugo 80

DRU Lugo 80 Bedienungsanleitung - Deutsch - 28 seiten

DRU Lugo 80 Installationsanweisung - Deutsch - 44 seiten

DRU Lugo 80 Bedienungsanleitung - Englisch - 28 seiten

DRU Lugo 80 Bedienungsanleitung - Holländisch - 28 seiten

DRU Lugo 80 Installationsanweisung - Holländisch - 44 seiten

DRU Lugo 80 Bedienungsanleitung - Französisch - 28 seiten

DRU Lugo 80 Installationsanweisung - Französisch - 44 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info