2.1 Changing of Personal Code
1. Type in the access code that is to be changed. The buzzer beeps
twice to confirm that it is correct, otherwise it indicates an error with a
long beep.
2. Press the
C
**
key. The message «INSERT NEW CODE» appears
on the display.
3. Enter the new code. The message «RE-INS NEW CODE» appears
on the LCD display.
4. Enter the new code a second time.
If the new code has been correctly entered, it is accepted and this is
confirmed when the buzzer beeps twice; otherwise, an error warning
is given and the procedure is exited.
Example of code change
- The Master user wishes to change the factory code 1-11111.
- Type in 111111 on the keypad and press the
C
**
key. The message
“ENTER NEW CODE” appears on the display.
- Enter the new code, for example, 165744. The message “RE-ENTER
NEW CODE” appears on the LCD display. Now re-type the numbers
165744.
- The buzzer beeps twice to confirm acceptance of the new code.
1. Enter the MASTER User code.
2. Press the
F
key and then the
C
**
key. The message “ENABLE
CODE” appears on the display.
It is now possible to enable/disable the engineer’s code, the
telemonitoring code, the User 2 code and the key code. These 4 codes
are associated with the 4 leds present on the keypad:
ENGINEER
TELEMONITORING
USER 2
KEY CODE (EK)
3. Press the key next to the led to enable/disable the corresponding
code
4. Press the
EXIT
F
key to exit the procedure.
Note: the first number
of the code must be the
user’s identification
number:
1 for the Master user
2 for User 2
3 fo r the engineer
4 for telemonitoring
5 for User 5
6 for User 6
7 for User 7
8 for User 8.
2.2 Enabling/Disabling of the User 2,
Engineer’s, Telemonitoring and Key Codes
The key code cannot be
changed: when enabled, it
allows use of the electronic
keys and of the commutators.
When disabled, it prevents
the operation of all the
commutators and of existing
keys (only system status will
be displayed by the
commutators’ leds).
KEY
CODE
The leds respectively indicate the
status of codes
Led ON = Code enabled
Led OFF = Code disabled
5
3.
Arming/Disarming
Commutator leds 1 (zone 1), 3 (zone 2) and 4 (zone 3) indicate the
system’s current status:
ON = armed zones
OFF = disarmed zones
1. Insert the commutator key and leave it inserted.
2. If the key inserted controls only one of the three zones, the status of
the zone for which the key operation is enabled changes immediately.
3. If the key controls more than one zone, the system cyclically indicates
the possible combinations that can be applied for a maximum of 4
times.
If the key controls two zones, the system displays the following
sequence:
If the key controls all three zones, the system offers the following
sequence:
Removal of the key with one of these combinations set causes
permanent arming of the selected mode and triggers the exit delay
procedure (when programmed). With the key permanently inserted,
at the end of the fourth cycle, the system exits the procedure and
remains in the previous mode.
ON = ZONE 1 ARMED
OFF = ZONE 1 DISARMED
ON = ZONE 2 ARMED
OFF = ZONE 2 DISARMED
ON = ZONE 3 ARMED
OFF = ZONE 3 DISARMED
1 1 ON - 3 ON removal of key arms both zones
2 1 ON - 3 OFF removal of key arms zone 1
3 1 OFF - 3 ON removal of key arms zone 2
1 1 ON 3 ON 4 ON removal of key arms all three zones
2 1 ON 3 OFF 4 OFF removal of key arms zone 1
3 1 OFF 3 ON 4 OFF removal of key arms zone 2
4 1 ON 3 ON 4 OFF removal of key arms zones 1 and 2
5 1 OFF 3 OFF 4 ON removal of key arms zone 3
6 1 ON 3 OFF 4 ON removal of key arms zones 1 and 3
7 1 OFF 3 ON 4 ON removal of key arms zones 2 and 3
36
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Elkron MP110 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Elkron MP110

Elkron MP110 Bedienungsanleitung - Deutsch - 32 seiten

Elkron MP110 Bedienungsanleitung - Französisch - 120 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info