621095
10
Zoom out
Zoom in
Vorherige Seite
1/23
Nächste Seite
- 19 -
Press this button to escape from this screen, and return to Camera Setup display. If the Save dialog is shown, press ENTER to
exit and save, ESC to exit without saving.
The following is a brief description for each item and its specific operations:
Duration response duration to define at most how long (in seconds) the Alarm Out relay and the Buzzer will keep being
triggered after motion is detected for this camera. However, the Alarm Out relay and the Buzzer will be reset immediately
once the camera returns to normal. Press +/- buttons to adjust the value (3-60 seconds, discrete).
Goto Preset to define the preset position to go to if motion is detected and this camera is a PTZ camera. For more details
about preset locations, please refer to Chapter 7 PTZ Control.
P
re-recordto define how long before motion is detected this camera shall be intensively recorded at Pre-record IPS. Press
+/- buttons to adjust the value (0-10 seconds, discrete). Please note that the actual pre-record time may be shorter than the
value set if the total size of the pre-record pictures exceeds the pre-record buffer size of the system.
Post-recordto define how long after motion is detected this camera shall be intensively recorded at Event Record IPS. Press
+/- buttons to adjust the value (0 second - 60 minutes, discrete).
Alarm Out to define which Alarm Output will be triggered when motion of this camera is detected. Press +/- buttons to
select none (N/A) or one of the Alarm Outputs (1-2).
B
uzzer – to activate the internal Buzzer or not when motion of this camera is detected. Press ENTER or +/- to check/uncheck
this item. The default setting is “ˇ
ˇˇ
ˇ ” - checked.
Log – to log to event logs or not. Press ENTER or +/- to check/uncheck this item. The default setting isˇ
ˇˇ
ˇ
- checked.
S
creen Message to display the event message on the screen or not. Press ENTER or +/- to check/uncheck this item. The
default setting is “ˇ
ˇˇ
ˇ ” - checked.
E
-mailto send the event e-mail to remote station or not. The e-mail will be sent to the predefined receivers when the event
is triggered. Press ENTER or +/- to check/uncheck this item. The default setting is “
” - unchecked.
Detection Settings.. used to setup the motion detection settings, including detection area and sensitivity, when motion is
detected for this camera. Press ENTER in Settings.. to call up Motion Detection Setup (as shown) for this camera. In Motion
Detection Setup, the video area is divided into many small grids, and the area with transparent grids is the area which will be
detected for motion, while gray grids not detected for motion. Besides, there is a (green) Mask window.
The following is a brief description for the operations:
Numeric
Press these buttons to select the camera.
◄►
Press these buttons to move the Mask window.
+
/-
Press these buttons to resize the Mask window.
E
NTER
Press this button to set/reset the area under the Mask window.
M
ODE
Press this button to set/reset the whole video area.
S
EQ
- 20 -
Press this button to decrease the sensitivity, from 10 – 1, for the motion detection of this camera.
C
ALL
Press this button to increase the sensitivity, from 1 – 10, for the motion detection of this camera.
SEARCH
Press this button to test the motion detection of this camera. The detected motion will be shown on the screen. Press this
button again to stop testing.
ESC
Press this button to escape from Motion Detection Setup, and return to Motion Setup.
6.3 Alarm Setup
In Setup Menu display, press
to change the highlighted option to Alarm, and then press ENTER to call up Alarm Setup
display as shown. The Alarm Setup allows the administrator to define the attributes for each alarm input, and the actions if it’s
triggered. There are up to 4 alarm inputs which can be connected to the system.
The general operations are as follows:
◄►
Press these buttons to select the items.
Numeric
Press these buttons to select the alarm input.
C
OPY ( )
Press this button to copy the settings of the focus alarm input to all the following alarm inputs. (eg. focus alarm input is 1, its
settings will be copied to those of alarm inputs 2-4.)
ESC
Press this button to escape from this screen, and return to Setup Menu display. If the Save dialog is shown, press ENTER to
exit and save, ESC to exit without saving.
The following
is a brief description for each item and its specific operations:
Normal State press +/- buttons to select N/A, Close or Open. Please check the signal type, normally close or normally open,
connected to the alarm input terminal on the rear panel of the system. If there’s no signal connected, please select N/A Not
Available, and the following items will not be settable. The default setting is Open.
Focus Camera – the camera corresponding to this alarm input.
Duration response duration to define at most how long (in seconds) the Alarm Out relay and the Buzzer will keep being
triggered after this alarm input is triggered. However, the Alarm Out relay and the Buzzer will be reset immediately once this
alarm input returns to normal. Press +/- buttons to adjust the value (3-60 seconds, discrete).
Goto Preset – to define the preset position to go to for the Focus Camera if this alarm input is triggered and the Focus Camera
is a PTZ camera. For more details about preset locations, please refer to Chapter 7 PTZ Control
.
Pre-record to define how long before this alarm input is triggered the Focus Camera shall be intensively recorded at
Pre-record IPS. Press +/- buttons to adjust the value (0-10 seconds, discrete). Please note that the actual pre-record time may
be shorter than the value set if the total size of the pre-record pictures exceeds the pre-record buffer size of the system.
Post-recordto define how long after this alarm input is triggered the Focus Camera shall be intensively recorded at Event
Record IPS. Press +/- buttons to adjust the value (0 second - 60 minutes, discrete).
Alarm Outto define which Alarm Output will be triggered when this alarm input is triggered. Press +/- buttons to select
none (N/A) or one of the Alarm Outputs (1-2).
Buzzerto activate the internal Buzzer or not when this alarm input is triggered. Press ENTER or +/- to check/uncheck this
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Elro DVR154S wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Elro DVR154S

Elro DVR154S Bedienungsanleitung - Deutsch - 24 seiten

Elro DVR154S Bedienungsanleitung - Holländisch - 22 seiten

Elro DVR154S Bedienungsanleitung - Französisch - 19 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info