696805
8
Zoom out
Zoom in
Vorherige Seite
1/20
Nächste Seite
Installation manual
8
1 Dear user
Congratulations on purchasing your Faber product, a quality
product that will provide you with the warmth and atmosphere for
many years. Please read the user manual before using the re.
Should a malfunction occur despite the careful nal checks, then
you can always contact your Faber dealer.
In order to claim the guarantee, it is important that you register the
re. For this we have created a special site. You will nd all
information regarding the warranty during registration.
> Please note:
The data of your re is available in the user manual.
1.1 Introduction
Installation and maintenance of the re must be carried out by a
professional expert who has proven knowledge and demonstrable
competence. A professional craftsman takes into account all
technical aspects such as heat delivery, gas connection as well as
ue gas discharge requirements.
Where the installation instructions are not clear, he must follow
national / local regulations.
1.2 Please check
You can register your re at: www.faber-res.eu
Check the re for transport damage and report any damage
immediately to your dealer.
1.3 CE-declaration
Glen Dimplex Benelux certies that this Faber re complies with the
essential requirements of the gas appliances directive.
Product: gas room heater
Model: Vejen
This appliance complies with the Gas Appliance Regulation (EU)
2016/426.
Harmonized standards applied: EN 613 2000/A1 2003.
This declaration is invalid, if without the written permission of Glen
Dimplex Benelux:
- Changes are made to the appliance.
- The re is connected to other exhaust materials than
specied.
2 Safety instructions
> Please note:
It is advisable to always install a screen for the replace if children,
elderly or disabled people are present in the same room as the
replace. If regularly vulnerable persons can be present in the
room without supervision, sufcient protection must always
be placed around the replace.
• The appliance is designed for atmospheric and heating
purposes. This means that all visible surfaces, including the
glass, can become hotter than 100 ° C. An exception to this
is the underside of the replace and the control buttons.
Do not use the remote control and / or app outside the room
where the re is located. So that you are always aware of the
situation around the replace when it is being operated.
The unit must be installed and subsequently serviced every
year and maintained in accordance with these instructions
and the applicable national and local regulations.
Ensure that the data on the type label matches the local gas
type and pressure.
The settings and the construction of the re must not be
changed!
Do not place extra imitation wood or other smoldering
material on the burner or in the combustion chamber.
Do not place any combustible materials within 1m of the
radiation area of the re.
Through the natural air circulation of the re moisture and
uncured volatile components from paint, building materials
and carpeted oors, etc. are attracted. These parts can settle
as soot on cold surfaces. Therefore do not light the re
shortly after installation.
Light the re for the rst time and run for several hours on the
highest setting, so that the paint can cure. Provide adequate
ventilation, so that any fumes can disperse; we recommend
vacating the room during this process.
> Please note:
1. All transport packaging is removed.
2. No children and pets in the room present.
3 Installation requirements
3.1 Minimum distance to combustible materials
around the re
Keep a minimum distance of 9cm to the back wall and 50cm
at the sides.
3.2 Flue pipe and terminal requirements
For the supply of the combustion air and the discharge of the
combustion gases you should always use the Flue materials
specied by Faber.
> Please note: Only when using these materials can Faber
guarantee the safe and proper operation of the appliance.
* This appliance must be installed in a chlorine-free
environment.
* The outside of the concentric ue material can heat up to
+/-150°C. Ensure, when penetrating a ammable wall or
ceiling, construction with proper insulation and protection.
Ensure sufcient clearance is maintained.
* Ensure that the concentric ue pipes are supported every
meter, so that the weight of the pipes is not supported by the
re.
* It is not permitted to start directly on the device with
concentric cut down pipe material.
The air supply could then possibly be closed.
3.3 Terminals
The combined supply and discharge can be done both via wall or
through the roof or through an existing chimney. Verify if the
position of the terminal meets the local regulations regarding
ventilation openings. The ue outlet can end on an external wall or
a roof.
Check whether the outlet desired by you complies with local
requirements concerning good function and ventilation systems.
> Please note:
For a proper functioning the terminal should be at least 0,5m. away
from:
Corners of the building
Roof overhangs and balconies
Eaves (with the exception of the roof ridge, see Chapter 15).
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Faber Vejen wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Faber Vejen

Faber Vejen Installationsanweisung - Deutsch - 28 seiten

Faber Vejen Installationsanweisung - Holländisch - 24 seiten

Faber Vejen Installationsanweisung - Französisch - 24 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info