696805
10
Zoom out
Zoom in
Vorherige Seite
1/20
Nächste Seite
Installation manual
10
6 Placing the decoration material
It is not permitted to use other or to add more material in the
combustion chamber.
Keep the pilot light always free of decoration material!
Place the glass plate on the bottom in the recesses on the
left and right. See g. 6.0a and b.
Spread the glass fragments over the glass panel (one layer)
and cover these with the supplied vermiculite grains.
(The amount of vermiculite affects the intensity of the glow
effect and can be done according to your own discretion).
Place the imitation logs. Make sure that the logs are properly
connected to the tube burners and rest on the bottom of the
re.
If necessary remove glass fragments and/or vermiculite
underneath the burners. (See the supplied log set instruction
card).
Spread the rest of the vermiculite and the chips over the
bottom of the burning chamber. Ensure that the air openings
are not covered.
Start the re as described in the user manual. Check the appearan-
ce of the ames and for burning against the vermiculite grains.
7 Checking the installation
7.1 Checking the ignition of pilot light and
main burner
Light the re as described in the user manual.
Check that the pilot ame is not covered by chips and/or an
imitation log.
Check the ignition of the main burner on full and low setting.
(ignition must be smooth and quiet).
7.2 Checking for gas leaks
Check with a gas leak nder or spray all connections and pipes for
gas leakage.
7.3 Checking the burner pressure and
primary pressure
Check that the burner pressure and primary pressure match with
the information listed in the manual. See Chapter 14.
Measuring the primary pressure:
Close the shut-off valve.
Turn measuring nipple A (see g. 8.0) some few turns open
and connect a measuring hose to the gas regulator.
Take this measurement at highest setting of the re and when
the re is set to pilot light.
Do not connect the unit if the pressure is too high.
Measuring the burner pressure:
Check the burner pressure only with proper primary pressure!
Turn measuring nipple B (see g. 8.0) some few turns open
and connect a measuring hose to the gas regulator.
The pressure must correspond to the value indicated in the
technical specications of this manual. In case of deviation
contact the manufacturer.
> Please note:
Close all pressure measuring nipples and check for gas leakage.
7.4 Checking the ame image
Let the re burn for at least 20 minutes at highest setting and check
the ame for:
Flame distribution
Color of the ames
If one or both points are not acceptable then check:
The log set layout and/or the amount of glass granulate/chips
on the bottom plate.
The pipe connections for leaks (in case of blue ames).
Whether the correct ue restrictor is tted. See g. 9.0.
• The outlet.
o Wall terminal right side up
o Roof terminal on the right position
o If the maximum horizontal ue lengths is not exceeded.
8 Instructions for the client
Recommend that the unit should be checked annually by a
qualied specialist to ensure the safe use and to guarantee a
long service life.
Give advice and instructions on care and cleaning of the
glass. Highlight the danger of burnt-in ngerprints.
Instruct the customer on the operation of the appliance.
Hand over to customer:
o Installation manual
o User manual
o Log set instruction card
9 Annual maintenance
9.1 Checking and cleaning
Check and clean if necessary after verication:
o the pilot light
o the combustion chamber
o the glass
o the logs for breakage
o the outlet
o the wiring/contacts for corrosion
Replace, if necessary:
o chips/vermiculite
o Glass granulate
9.2 Cleaning the glass
Most deposits can be removed with a dry cloth. Clean the glass
with Faber glass polish..
> Please note:
Avoid ngerprints on the glass. These are no longer removable
after they are burnt in!
Now carry out check-up as described in Chapter 7.
10 Conversion to other gas type
Conversion to another type of gas can only be carried out by a
qualied installer / dealer.
To do so, please contact your dealer.
Specify with your order always the type and serial number of the
device.
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Faber Vejen wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Faber Vejen

Faber Vejen Installationsanweisung - Deutsch - 28 seiten

Faber Vejen Installationsanweisung - Holländisch - 24 seiten

Faber Vejen Installationsanweisung - Französisch - 24 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info