ACTIVATING THE ALARM SYSTEM.
The alarm can be activated by pressing key no.1 on the remote or by inserting the electronic key into
the appropriate socket. The operation is confirmed by a visible signal consisting of one flash of the turn
indicators lasting approximately one second. While the visible signals are being emitted, the following
functions are enabled:
a) Module output (PINK wire / +A)
b) LED output (lit continuously to indicate neutral activation time)
c) Engine blocks
d) Activation of door-locking control (with the timing selected at programming phase).
If the electronic key is used, all the functions described under points a), b) and c) will be activated,
whereas d) ACTIVATION OF DOOR-LOCKING CONTROL will not occur (enabling the user to get out
of the vehicle).
Moreover, by using the electronic key, a car entry time of approximately 10 seconds will be generated
to allow the user to get into the car and deactivate the alarm system with the electronic key without
creating a fals e alarm.
While the user gets into the car, entry time is indicated by the continuous light of the LED.
NEUTRAL ACTIVATION TIME CUTTING OUT THE EXTERNAL SENSORS / STOPPING WINDOW UPWARD TRAVEL /
COMFORT.
Neutral activation time lasts approx. 35” and it is indicated by the continuous light of the LED. This time
interval allows the user to get out of the vehicle without causing false alarm conditions. During the first
25” of the neutral time, it is possible to cut out the external sensors and stop the windows’ upward
travel by pressing key no. 2 on the remote (Note: the stop window function requires the installation of a
special module see art. 2344 – or the existence of the COMFORT function in the car).
THE ACTIVATION OF SAI D FUNCTIONS (CUTTING OUT THE EXTERNAL SENSORS / STOPPING WINDOW
UPWARD TRAVEL / COMFORT) IS INDICATED BY A BRIEF FLASH OF THE TURN INDICATORS.
NOTE: SENSOR CUTOUT IS LIMITED TO A SINGLE AL ARM ACTIVATION CYCLE.
CUTTING OUT THE SIREN .
To cut out the sound of the siren and enable the alarm signal only through the turn indicators you must
follow this procedure:
a) With the system off, turn the ignition key to the ON position the LED will light up for about 0.5
seconds.
b) While the LED is ON (0.5 seconds), press key no.2 on the remote the LED will immediately go
out.
The siren, including the supplementary external siren or the original horns, will be cut out during the
next alarm activation cycle. To reactivate the siren, just deactivate and reactivate the alarm system.
SYSTEM READY AFTER NEUTRAL TIME.
At the end of the neutral time (approx. 45”), the security system is completely armed and ready to
intervene in cases of attempted theft or sabotage.
Completely armed status is indicated by the flashing of the LED, which will wok according to the
following timing scheme in order to minimise power consumption:
LED ON : 200MS
LED OFF : 2”
EVENTS THAT CAN GENER ATE AN ALARM CONDITION:
a) SYSTEM WIRE CUTTING BY MEANS OF THE SELF -POWERED SIREN .
b) ATTEMPT TO START THE ENGINE.
c) POWER DRAINED. (THIS FUNCTION IS ACTIVE ONLY IF ENABLED IN THE ACCESSORY FUNCTION
PROGRAMMING PHASE AND CAN BE USED ONLY IN COUNTRIES WHERE THE LAW DOES NOT PROHIBIT THE
USE OF THIS SENSOR ).
d) ATTEMPT TO OPEN THE DOORS
e) ATTEMPT TO OPEN BOOT.
f) ATTEMPT TO OPEN ENGINE BONNET.
g) INTRUSION DETECTED BY INTERNAL ULTRASOUND VOLUME SENSOR.
h) INTRUSION DETECTED BY EXTERNAL SENSORS (OPTION) (ALSO BY RADIO ).
i) PANIC ALARM BY PRESSING KEY NO. 2 ON THE REMOTE (THIS FUNCTION IS ACTIVE ONLY IF
ENABLED IN THE ACCESSORY FUNCTION PROGRAMMING PHASE AND IT CAN BE USED ONLY IN COUNTRIES
WHERE THE LAW PERMITS THIS TYPE OF ALARM ACTIVATION NOT AVAILABLE IN PRODUCT
VERSION FOR THE DUTCH MARKET).
NOTE: In order to filter noise and/or undesired signals, the POSITIVE POLE UNDER KEY, DOORS
PUSHBUTTON and BOOT PUSHBUTTON inputs have a DEBOUNCE time of 200mS. Therefore
these inputs will cause the generation of an alarm cycle only if the signals coming in last longer than
200mS.
ALARM CYCLE.
An alarm cycle generated by an attempt to break in consists of the activation of the sirens
connected to the alarm device (unless previously cut out) and the flashing of the turn
indicators (with a timing scheme of 0.5” ON 0.5” OFF) for a maximum time period of 30”.
The supplementary siren/ original car horn output will have the following characteristics as
a function of type of programming chosen at the installation phase:
SUPPLEMENTARY SIREN OPERATION :
Continuous audible signal for the entire duration of the alarm signal cycle.
ORIGINAL HORN OPERATION :
Intermittent sound 2” ON – 2” OFF for the entire duration of the alarm signal cycle.
If the user has cut out the siren, the alarm condition will be indicated solely by the flashing of the turn
indicators for a maximum time period of 30”.
NOTE: While the alarm signal is given out, the LED will emit a continuous light.
You can cut off the alarm cycle without deactivating the system, by pressing key no. 2 on the remote.
As you do so, the audible/visible alarm signals will be immediately cut off, and the system will switch to
the condition of NEUTRAL TIME BETWEEN SUCCESSIVE ALARMS.
To minimise acoustic pollution, the DOORS PUSHBUTTON, BOOT PUSHBUTTON, BONNET
PUSHBUTTON, ELECTRICAL INPUT SENSOR, INTERNAL VOLUME SENSOR and EXTERNAL
SENSORS inputs are subject to a limitation of up to five alarm cycles per system activation period. The
count is reset upon the next deactivation of the alarm system or if an alarm for POSITIVE POLE
UNDER KEY intervenes during the same activation cycle,.
NOTE: THE POSITIVE POLE UNDER KEY INPUT AND THE WIRE CUT FUNCTION (BY MEANS OF THE
SELF-POWERED EXTERNAL SIREN ) HAVE NO ALARM LIMITS.
NEUTRAL TIME BETWEEN SUCCESSIVE ALARMS.
At the end of each alarm cycle there is a neutral time period, lasting up to approx. 5”, during which
there will be no reaction to the causes of alarm. During the neutral time between successive alarms,
the LED will emit a continuous light. Normal flashing will be resumed at the end of the neutral time.
DEACTIVATING THE ALAR M SYSTEM.
The alarm system can be deactivated by pressing key no.1 on the remote, or by inserting the
electronic key into the appropriate socket (or by means of an emergency PIN-CODE procedure during
the neutral time between successive alarms).
Following this action, the centralized door-unlocking command will be implemented at once, according
to the timing programmed at the installation phase, and two different types of confirmation signals will
be generated:
1) DEACTIVATION WITHOUT ANY ALARM CONDITION BEING INDICATED: If no theft or break-in
attempts have been detected during the surveillance period, the system will give out a visible
signal consisting of three flashes of the turn indicators.
2) DEACTIVATION WITH INDICATION OF ALARM CONDITIONS: If one or more attempted thefts or
break-ins have been detected during the surveillance period, the system will give out a visible
signal consisting of 5 flashes of the turn indicators.
WHEN THE ALARM SYSTEM IS DEACTIVATED, THE FOLLOWING OUTPUTS / FUNCTIONS ARE DISABLED :
a) EXTERNAL SELF-POWERED SIREN
b) MODULE OUTPUT (PINK wire / +A)
c) LED OUTPUT
d) ENGINE BLOCK function
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gemini 7590 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info