Electric safety:
DANGER! Electric shock!
Risk of injury by electric shock!
Pull the plug out of socket before fill of the pump, after
switching it off, at repair removal and before
maintenance.
Operate the appliance on connectors with an earth-
leakage circuit-breaker (RCD)!
Please consult with an electrician.
Information on the type label must correspond to information
of the electric network.
Protect the cable against high temperatures, oil and sharp
edges.
General instructions:
Before using the pump, always execute a visual inspection
to detect any damage of the pump, especially the line cord
and plug.
A damaged pump must not be used.
In case of any fault, have the pump checked in a service
department of GUDE or at an authorised electrician.
Do not expose the pump to rain and do not use it in a moist or
wet environment.
To prevent the pump from running dry, please make sure the
end of the suction hose was always plunged in the pumped
medium.
Fill the pump with the pumped liquid until it overflows before
each starting!
When the pump is used as a home pumping station, local
regulations of a water company need to be observed.
Moreover, provision of the DIN 1988 standard must be
obeyed.
Behaviour in emergency
Provide first aid of a corresponding nature and level of injury
and call qualified medical help as soon as possible.
Rest the injured person in peace and in a manner he/she did
not sustain any other injury.
Appliance use as designed
The pump is solely designed to pump clear water to supply
water to a house, garden, court and agriculture. If the
generally binding regulations and provision of these
Instructions are not observed the producer cannot be held
liable for any damage.
Residual risks and protective measures
Electric residual risks
Threat Description Protective measures
direct electric
contact
electric shock earth-leakage circuit-breaker
indirect
electric
contact
electric shock
through
pumped
medium
earth-leakage circuit-breaker
Disposal
The disposal instructions are based on icons placed on the
package or appliance. The description of individual meanings
can be found in the “Marking on appliance“ chapter.
Handling requirements
The operating staff must carefully read and understand the
Operating Instructions before using the appliance.
Qualification
Apart from the detailed instructions by a professional, no
special qualification is necessary for appliance using.
Minimum age
Persons over 16 years of age can only work on the appliance.
An exception includes use by youngsters if the appliance is
used under supervision of trainer within occupational
preparation and its use serves to reach the necessary
knowledge.
Training
Appropriate training executed by a competent person,
knowing the Operating Instructions, is only necessary for
using of the appliance. No special training is necessary.
Technical data
HWA 1200 IC
Supply voltage 230 V / 50 Hz
P1 engine power 1200 W/P1
Max. suction lift 8 m
Max. amount pumped 3,800 l an hour
Max. head of delivery 50 m
Discharge connector 1“
Suction connector 1’’
Protection type IP 44
Water temperature 35 °C
Weight app. 12,4 kg
Product No. 94207
Transport and storing
When storing the appliance for a winter period it is
necessary to make sure there is no water in the appliance as
frost could be a cause for appliance damage.
At each transport and carrying, the appliance must be
disconnected from electric current source!
Assembly and first putting into operation
Filter and sludge screen
At pumping water with sand contents, the pump needs to be
operated with a sludge filter (available as accessory) for the
suction connector. Sand entering the mechanical seal
(propeller shaft engine - pump) would damage the pump! That
would mean, even during the guarantee time, your own fault
and the guarantee does not relate to such failures.
Safety instructions for first putting the pump into
operation
Attention: the pump must never run dry.
Do not use the pump for pumping drinking water!
The user is responsible to other persons as far as pump
(pumping station, etc.) operation is concerned.
Operate on connectors fitted with an earth-leakage
circuit-breaker only!
Before putting the appliance into operation, a competent
electrician must check that the appliance disposes of the
required electric safety elements.
Wiring is done to a socket. Check the voltage. Technical data
specified on the label must correspond with the electrical
network voltage.
If you use the pump for small lakes, wells, etc. and pumping
stations you must follow appropriate standards of the country in
which the pump is used.
Electrical pumps used outdoor must be fitted with a rubber
H07RNF-type electric cable corresponding to DIN 57282 or DIN
57245 standards.
When the pump is in operation, there must be no people
or animals in the pumped liquid (e.g. in pools, cellars,
etc.)
The temperature of the pumped liquid must not exceed +35
°C. If you use an extension cable it must be solely of rubber,
the H07RNF type, corresponding to DIN 57282 or DIN
57245 standards. Never touch, lift or carry a pump
connected to electrical network with a cable. Make sure
there is no water or moisture in the connecting socket and
the plug was protected against moisture.
31
31

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

gude-hwa--1200-ic

Suche zurücksetzen

  • meine HWA1200 ic bringt nur noch max. 2bar.
    aus diesem Grund schaltet der Druckschalter auch nicht mehr ab.
    muß ich da etwas austauschen? Eingereicht am 8-7-2021 12:01

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gude HWA 1200 IC wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info