Before putting the pump into operation, check that the electric
cable or socket are not damaged.
Before executing any work on the pump, the pump needs to
be disconnected from electrical network.
If the pump needs to be installed in a gulley, the gulley
needs to be subsequently closed with a cover to ensure
safety of pedestrians.
Do not in any case install the pump in wet pits (risk of
short-circuit, damage by corrosion)!
To prevent occurrence of damage that can be caused
as a result of any faulty function of the pump (e.g.
flooded rooms, etc.), the owner (user) is obliged to take
reasonable safety measures (alarm installing, spare
pump, etc.).
If the pump is faulty the repair can only be executed by an
authorised service only. Using original spare parts is
allowed only.
Let us refer to the fact that according to valid standards
we do not assume any responsibility for damages
caused by our appliances as a result of the below-
mentioned causes.
Any unsuitable repairs executed by unauthorised services.
Using the appliance in conflict with its purpose or failure to
observe the prescribed use.
Pump overloading with continuous run.
Fuse against thermal overloading
Inside the electric motor, there is a probe automatically
switching the pump off when a specific temperature is
exceeded and on again after cooling down. That many times
increases the pump life and prevents thermal damage of the
electric motor.
Protection against overloading/thermal motor control
switch
The cooling down time is app. 25 minutes, then the pump is
automatically switched on again. Prevent therefore
dangerous situations caused as a result of automatic start of
the pump. When the motor control switch goes off or on, it is
necessary to identify the cause and remove it (see also the
“Failure diagnostics“). Do not regard the information
mentioned there as instructions for “home-made“ repairs as
professional knowledge is necessary for repairs. Always
contact the customer service at any failure.
It is necessary to ensure corresponding air supply to
prevent pump overheating!
Do not install in tight or wet pits and do not cover!
Pressure sensor
The electronic pressure sensor with integrated protection
against dry run will automatically switch the pump off when
you close the appliance and switches on when you open it.
Stopping at dry run: Stopping at dry run is notified through
the red FAILURE indicator when the engine is off. To
restore the equipment to original state it is enough to press
the RESET button after you make sure water flows in the
pump suction.
Handling
Safety instructions for handling
Use the appliance only after you have properly read the
Operating Instructions. Follow all safety instructions specified
in the Operating Instructions. Behave responsibly to other
persons.
Use suction sets with a clack-valve only.
Carefully fill the suction hose with water.
Attention: Do not fill via the switch => screw the switch
only after filling!
Attention: Small appliances can cause failures =>
increase water inlet.
Deaeration
To deflate any air from the conduct, loosen the bleed
screw (pic. A; pos. 2)
Water discharge
Loosen the drain screw to fully discharge the pump (pic.
A; pos. 4)
Detailed instructions
Connect the suction tube with a clack-valve (foot
valve) corresponding to the suction connector.
Always tighten all threaded connectors with a
weather strip.
If you want to fill the pump unscrew the bleed screw
at the back part of the pump and on water delivery
main connector (pic. A; pos. 2 and 1). Fill the
appliance until water flows out through the air hole.
(D)
Tighten the bleed screw and screw it up again. Then
tighten the water delivery main in the place of the
connector and close it tightly.
Plug the pump.
Attention: At assembly of the suction piping
and water delivery main on appropriate connectors,
always properly screw appropriate threads to prevent
damages as a result of any deterioration of the pump
housing!
Attention: Careful sealing of threaded
connections and filling of the suction system without
access of air (B and D) - (suction hose and pump
housing) will ensure successful working of the pump!
Check the foot valve tightness (C) – fill the system
according to given instructions (B) and pull the suction
hose out of the medium before starting to check it – the
liquid can only flow out of the suction hose!
Important: If the pump is to be out of order for a longer
time it is necessary to empty the tube and housing of
the pump. Protect the pump against frost. The pump
can only be stored when absolutely emptied.
32
32

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

gude-hwa--1200-ic

Suche zurücksetzen

  • meine HWA1200 ic bringt nur noch max. 2bar.
    aus diesem Grund schaltet der Druckschalter auch nicht mehr ab.
    muß ich da etwas austauschen? Eingereicht am 8-7-2021 12:01

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gude HWA 1200 IC wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info