771611
22
Zoom out
Zoom in
Vorherige Seite
1/148
Nächste Seite
Page 22
Page 22
Installation Of The Throttle. (Some Models)
Indoor
Indoor
Indoor
Outdoor
Outdoor
Outdoor
1 Throttle
2 Liquid pipe
3 Gas pipe
Precautions
- For ensuring throttled efciency, please
mount the throttle as horizontally as possible.
- Wrap the supplied anti-shock rubber at
external of the throttle for denoise.
1 Anti-shock rubber
2 Throttle
CAUTION
Ensure to wrap insulation around the
piping. Direct contact with the bare piping
may result in burns or frostbite.
Make sure the pipe is properly connected.
Over tightening may damage the bell
mouth and under tightening may lead to
leakage.
NOTE ON MINIMUM BEND RADIUS
Carefully bend the tubing in the middle
according to the diagram below. DO NOT
bend the tubing more than 90° or more than
3 times.
Bend the pipe with thumb
min-radius 10cm (3.9”)
Fig. 6.10
6. After connecting the copper pipes to the
indoor unit, wrap the power cable, signal
cable and the piping together with binding
tape.
NOTE: DO NOT intertwine signal cable with
other wires. While bundling these items
together, do not intertwine or cross the
signal cable with any other wiring.
7. Thread this pipeline through the wall and
connect it to the outdoor unit.
8. Insulate all the piping, including the valves
of the outdoor unit.
9. Open the stop valves of the outdoor unit
to start the flow of the refrigerant between
the indoor and outdoor unit.
CAUTION
Check to make sure there is no refrigerant
leak after completing the installation work.
If there is a refrigerant leak, ventilate the area
immediately and evacuate the system (refer
to the Air Evacuation section of this manual).
Page 23
Wiring 7
Safety Precautions
WARNING
Be sure to disconnect the power supply
before working on the unit.
All electrical wiring must be done
according to local and national regulations.
Electrical wiring must be done by a
qualied technician. Improper connections
may cause electrical malfunction, injury
and fire.
An independent circuit and single outlet
must be used for this unit. DO NOT plug
another appliance or charger into the same
outlet. If the electrical circuit capacity is not
enough or there is a defect in the electrical
work, it can lead to shock, fire, unit and
property damage.
Connect the power cable to the terminals
and fasten it with a clamp. An insecure
connection may cause fire.
Make sure that all wiring is done correctly
and the control board cover is properly
installed. Failure to do so can cause
overheating at the connection points, fire,
and electrical shock.
Ensure that main supply connection is
made through a switch that disconnects
all poles, with contact gap of a least 3mm
(0.118”).
DO NOT modify the length of the power
cord or use an extension cord.
CAUTION
Connect the outdoor wires before
connecting the indoor wires.
Make sure you ground the unit. The
grounding wire should be away from gas
pipes, water pipes, lightning rods,
telephone or other grounding wires.
Improper grounding may cause electrical
shock.
DO NOT connect the unit with the power
source until all wiring and piping is
completed.
Make sure that you do not cross your
electrical wiring with your signal wiring, as
this can cause distortion and interference.
Follow these instructions to prevent distortion
when the compressor starts:
No other equipment should be connected
to the same power circuit.
The unit’s power information can be found
on the rating sticker on the product.
The unit must be connected to the main
outlet. Normally, the power supply must
have a low output impedance of 32 ohms.
NOTE: The fuse is made of ceramic.
TAKE NOTE OF FUSE SPECIFICATIONS
The air conditioner s circuit board(PCB) is
designed with a fuse to provide overcurrent
protection. The specications of the fuse are
printed on the circuit board, such as:
Indoor unit: T3.15A/250VAC, T5A/250VAC.
(applicable for unit adopts R32 refrigerant)
Outdoor unit: T20A/250VAC.
,
22

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Inventor V6MCRI32-18WiFiR wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Inventor V6MCRI32-18WiFiR

Inventor V6MCRI32-18WiFiR Bedienungsanleitung - Deutsch, Englisch - 76 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info