Installation manual: Oa sis security system JA -80K - 14 - MKE51801
Unsetting (disarming) the system w ith a final door detector
• If a final-door detector gets triggered in a set (armed) system,
an entrance dela y will begin with a durati on of bet ween 30 and
270 seconds.
• If a normal delayed detector gets trigg ered while the user
enters a building, the system starts an or dinary entrance delay
of between 5 and 45 seconds.
• If a final-door detector is triggered first, a longer entrance
delay will begin. If duri ng this delay an ordinary del ayed
detector is then triggered, the rem aining entrance delay will
then be shortened t o the delay associate d with detectors of
this kind.
Note: Only use status-reporting detectors such as the JA-80M or JA-
82M, or the hard-wired inputs of wireless keypads, or the hard-wired
inputs of a control panel as final-door detectors. This mode is unsuitable
for pulse detectors such as JA-80P motion detectors, or the hard-wired
inputs of JA-80E hard-wired keypads which also have a pulse reaction.
Factory default setting: No final-door detectors in the system.
12.24. Partial setting (arming) or system splitting
The control panel can be configur ed in three ways as follo ws:
• the entire system sets and unsets together or,
• the system partially sets and uns ets to protect only
certain parts of a house during the day, while p eople
are still present in the unset parts or,
• the system can be split into two independentl y
set/unset sections for two separate users and als o with
a common section if desired.
Program as follows to configure the system as desired:
66x
where x =0 = unsplit system (setting/u nsetting as an
entire system)
x=1 = partial setting (for setting sections A, AB,
or ABC)
x=2 = split system (sections A and B can be
set/unset independently by separate users,
with section C only being autom atically set
when both A and B are manually set)
Notes:
• For an unsplit system, all intruder detectors are set/unset
immediately after the user sets/unsets the system. Assigning wireless
devices, access codes and keyfobs to various sections of the syst em
has no effect in this mode.
• Partial setting is especially suitable for homes and apartments where
the user wishes to protect different parts of the premises during the
day. Detectors can be assigned to three sections, A, B and C. Using
setting (arming) key A on the system keypad, you can set sectio n A,
e.g. setting the garage area in the afterno on. Using setting key B you
can set sections A and B simultaneously e.g. in the evening before
going to sleep to protect the gar age (section A) and the ground floor
of the house (section B). The ABC total-setting button is used when
leaving the home to set all sections, A,B and C. If you then use a val id
access code or card for unsetting (disarming), all sections will be
unset. The assignment of codes or cards to sections has no effect in
this mode.
• A keyfob can also be used for partial setting control. Buttons
and
can be programmed to set and unset the entire system, and
buttons
+ can be programmed for setting (arming) sections A
and AB respectively to partially set the system. (see 12.40 for details
on partial setting by keyfob).
• Split system mode is especially suitable where two families (A and
B) live in a single house or two companies (A and B) share one
building. The system behaves as two independent systems, one being
section A and the other, section B. There is also a common section C
which is only set if section A and section B are set at the same time.
and is commonly used for shared entrances, doors etc. Detectors c an
be assigned to sections A, B or C. Access codes and cards can be
assigned to operate either section A or B (not both), or alternatively to
section C to access the entire building. The same is true for keyfob
access.
• Partial setting only has an effect on intruder detectors, i.e. detectors
with instant, delayed or next-delayed reactions. Detectors with fire,
tamper, panic and 24-hour react ions are always able to trigger their
kind of alarm immediately, whether their section is set (armed) or not.
Factory default setting: Unsplit system.
12.25. Automatic summer time (daylight saving time)
If enabled, this feature automatically offsets the system time to
that of summer time, or daylight saving time as it is also known,:
6801 automatic summer time enabled
6800 automatic summer time disabled
Note: If automatic summer time is enabled, the control panel’s internal
clock is automatically offset by +1 hour on March 31
st
at midnight. The
offset is then removed on October 31
st
at midnight to return to winter
time.
Factory default setting: automatic summer time disabled
12.26. Tamper alarm in response to an increase in
the number of triggered tamper sens ors
This feature allows permanen tly triggered tamper sensors to be
ignored:
6811 ignore permanently triggered tamper sen sors, i.e.
only react to an increase in the number of triggered
tamper sensors.
6810 react with a tamper alarm to all triggered tamper
sensors
Note: Ignoring permanently triggered tamper sensors is useful for
example when carrying a detached wireless keypad arou nd with you
during installation as this avoids unnecessary tamper indication.
Factory default settin g: react with a tamper alarm to all
triggered tamper sensors
12.27. Operating the PG outputs using ∗ 8 and ∗ 9
Using this feature the PGX and PGY output s can be controlled
from the keypad b y pressing the ∗ 8 and ∗ 9 keys (or keys
and
).
6821 control e nabled
6820 contro l disabled
Notes:
• The PG outputs can only be op erated from the keypad if they have
their ON/OFF or pulse functions enabled.
• In addition to controlling the PG outputs using keys
∗
8 and
∗
9, PG
outputs can also be controlled by access codes, access cards,
keyfobs and detector signals (see 12.40 and 12.41 for details).
• If a PG output should only be operated by a valid access code or
card, then control by
∗
8 and
∗
9 should be disabled and the codes and
cards should be programmed to control the PG outputs instead (see
12.41).
Factory default setting: control enabled
12.28. Permanent alarm status display for a set
system
The below sequence enab les the permanent display of alarm
status on the keypad unit, even if the system is set.
6831 permanent status display enabled
6830 display time a maximum of 3 minutes if any section is
set (armed)
Notes:
• European legislation requires status displaying to be suppressed
within three minutes of setting (arming) the system, no matter how
much or little of the system is set. This feature can be used to ignor e
this requirement if appropriate.
• The wireless keypad can continuously display the status if powered
by an external power supply. If powered by internal batteries the
keypad will turn off its display after 20 seconds of not being used ( in
Service Mode the display turns off after 15 minut es of no use by the
installer).