Examples on the configuration of Program Scan and
VFO Scan:
Configure the memory channels for specific band
segments such that the checkboxes for P1, P3 and
P5 are selected. Next, press F5 [SCAN]. Program
Scan starts and scanning is performed in the
frequency range registered for the respective
channels.
Configure the memory channels for specific band
segments such that all the checkboxes are
deselected and press F [SCAN]. Or press [VFO/
PRG] to switch the display to VFO SCAN. VFO Scan
is performed on the entire RX frequency band.
The checkbox will remain deselected for memory
channels that do not contain any operating data.
These checkboxes cannot be selected.
For more details on registering memory channels for
specific band segments, please refer to “Configuring
the Program Scan Frequency Range” on page 9-4.
Switching the Scan Speed
The time interval for switching the Program Scan (VFO Scan)
frequency can be configured in modes other than FM.
1 Press F3 [–] or F4 [+] while Program Scan (or VFO
Scan) is in progress.
The scan speed is shown below the frequency display.
.
The frequency switching interval changes as follows.
Scan Speed Display
Frequency Switching Interval
SCAN-SPD1 10 ms
SCAN-SPD2 30 ms
SCAN-SPD3 100 ms
SCAN-SPD4 150 ms
SCAN-SPD5 200 ms
SCAN-SPD6 250 ms
SCAN-SPD7 300 ms
SCAN-SPD8 350 ms
SCAN-SPD9 400 ms
Program Slow Scan
Program Slow Scan is a function that extends the frequency
switching interval (performs scan more slowly) using the
preconfigured frequency for performing Program Scan (frequency
point) and the frequencies before and after this point (segment).
Switching slowly between the specified frequency (frequency
point) and the corresponding segment allows the communication
status to be checked in detail.
To perform Program Slow Scan, register a frequency range to
a memory channel for specific band segments in advance.
Turning ON/OFF Program Slow Scan
To combine the use of Program Slow Scan while Program Scan is
running, set Program Slow Scan to ON in advance.
When scanned frequency falls in the segment for Program Slow
Scan during Program Scan, “SCAN-SLOW” is displayed on the
screen and the speed of frequency switching slows down.
Configure in Menu [4-02] Program Slow Scan
Setting Value Off/ On (default)
Configuring the Frequency Points for Program Slow
Scan
The frequency points for extending the frequency switching
interval during Program Slow Scan can be configured as follows.
Up to 5 frequency points can be configured for each memory
channel assigned to specific band segments (P0 to P9).
To configure the frequency points, register a band segment to
a memory channel for specific band segments in advance.
1 Press [M/V] to switch to the memory channel mode.
2 Press F7 [M.LIST] to display the Memory Channel
List screen.
.
3
Press F2 [ ] or F3 [ ], or turn the [MULTI/CH]
control to select a memory channel for specific
band segments.
4 Press F5 [SLW.SCN] to display the Program Slow
Scan screen.
.
10 SCAN
10-2
120

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Kenwood TS-890S wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Kenwood TS-890S

Kenwood TS-890S Bedienungsanleitung - Deutsch - 196 seiten

Kenwood TS-890S Bedienungsanleitung - Holländisch - 196 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info