5 Turn the Tuning control and align the “Current”
frequency as the frequency point for Program Slow
Scan.
6 Press any of the function keys (F2 [POINT 1] to F6
[POINT 5]) to configure the center point of the
preferred frequency range to perform Program
Slow Scan.
Pressing and holding the key clears the frequency point that
is stored.
Pressing and holding F7 [(CLR ALL)] clears all the
frequency points.
7
Press F1 [ ] to exit the Program Slow Scan
screen.
The display returns to the Memory Channel List screen.
8 Press [ESC] to exit the Memory Channel List screen.
Pressing a function key (F2 [Point 1] to F6 [POINT 5])
that already contains a frequency point overwrites the
frequency point with the new input.
When configuring a frequency point, frequencies that are
smaller than 10 Hz are rounded off.
Configuring the Segment for Program Slow Scan
The frequency switching interval during Program Scan slows down
in the preconfigured segment that contains frequencies before and
after the frequency point for Program Slow Scan.
Configure in Menu [4-03]
Program Slow Scan
Range
Setting Value 100/ 200/ 300 (default)/ 400/ 500 [Hz]
For example, when 500 [Hz] is selected, the frequency
switching interval is extended to a range of ± 500 Hz from
the frequency point.
Scan Hold
While Program Scan (VFO Scan) is performed in a mode other
than FM, changing the frequency by turning the Tuning or [MULTI/
CH] control pauses the scan operation for 5 seconds.
Signals can be received temporarily without stopping the scan
operation.
Configure in Menu [4-04]
Scan Hold
Setting Value Off (default)/ On
When Scan Hold is set to “On”, signals are received with
Program Scan paused for 5 seconds.
Memory Scan
Memory Scan allows the registered memory channel to be
automatically switched at a specific time interval for scanning.
There are 2 types of Memory Scan modes. All-channel Scan
performs scan on all the memory channels that are registered with
operating data, while Group Scan performs scan on a selected
group among the memory channels.
Performing Memory Scan
1 Press [M/V] to switch to the memory channel mode.
2 Press F5 [SCAN] to start memory scan.
Turning the [MULTI/CH] control allows the scan channel to
jump rapidly to the next or previous channels.
Pressing F5 [SCAN] again or pressing [ESC] ends Memory
Scan.
The scan direction is fixed at the ascending order.
The frequency switching interval during Memory Scan is
400 ms. However, when a CTCSS tone is received in the
FM mode, the frequency switching interval is extended
to 600 ms. During Memory Scan, “SCANNING” is
displayed instead of the scan speed.
Configuring All-channel Scan and Group Scan
1 Press [M/V] to switch to the memory channel mode.
2 Press and hold F5 [SCAN] to display the Memory
Scan group screen.
.
3
Press F2 [ ] or F3 [ ] to select a memory
group.
4
Press F4 [ ] or turn the [MULTI/CH] control to
select whether to start scanning of the memory
channels belonging to a memory group.
Pressing F4 [ ] each time selects (performs scan) or
deselects (does not perform scan) the checkbox.
When performing All-channel Scan, select the checkboxes
for all the memory groups.
Pressing F6 [SEL.ALL] selects the checkboxes for all
memory groups.
Pressing F7 [CLR.ALL] deselects the checkboxes for all
memory groups.
Memory channels are classified into memory groups as
follows. The classification of the memory groups and
channels cannot be altered.
Group
Memory
Channel
Group
Memory
Channel
0 00 to 09 6 60 to 69
1 10 to 19 7 70 to 79
2 20 to 29 8 80 to 99
3 30 to 39 9 90 to 99
4 40 to 49 P P0 to P9
5 50 to 59 E E0 to E9
5 Press [ESC] to end the process.
SCAN 10
10-3
121

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Kenwood TS-890S wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Kenwood TS-890S

Kenwood TS-890S Bedienungsanleitung - Deutsch - 196 seiten

Kenwood TS-890S Bedienungsanleitung - Holländisch - 196 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.