595131
19
Zoom out
Zoom in
Vorherige Seite
1/136
Nächste Seite
ENGLISH
19
ENG
Emptying the Container
Only permitted for dusts with occupational
exposure limits > 1mg/m
3
.
- Unplug.
-ASR 35 M AutoClean: Remove the suction hose,
close the suction opening (14) with the sealing
plug (13).
- Open the snap locks (10). Remove the upper part
(9) from the container (11).
- Tip out the container.
Dispose of the paper filter bag/fleece filter bag.
- Unplug.
- Pull on mask.
-ASR 35 M AutoClean: Remove the suction hose,
close the suction opening (14) with the sealing
plug (13).
- Open the snap locks (10). Remove the upper part
(9) from the container (11).
- Carefully pull back and remove the paper filter
bag (8)/fleece filter bag (7) from the suction
opening (14). Seal the flange of the paper filter
bag/fleece filter bag by folding over the cover.
- Dispose of the vacuumed material in accordance
with legal regulations.
Disposing of the PE Filter Bag
- Insert mains plug.
- Switch on the vacuum cleaner and vibrate the
filters: turn the switch (2) to the "IR" position.
- Switch off the vacuum cleaner: turn the switch (2)
to the "0" position.
- Pull on mask.
-ASR 35 M AutoClean: Remove the suction hose,
close the suction opening (14) with the sealing
plug (13).
- Open the snap locks (10). Remove the upper part
(9) from the container (11). Before setting down
the upper part, turn switch (2) to the "I" position
so that any falling dust is vacuumed.
- Carefully pull back the PE filter bag (6) from the
suction opening (14). Seal the flange of the PE
filter bag by folding over the cover.
- Dispose of the vacuumed material in accordance
with legal regulations.
9.2 Special cleaning instructions for
ASR 35 M AutoClean:
In the case of class M machines, the outside of the
machine should be cleaned (vacuumed and wiped
down), or treated with sealants before being
removed from the hazardous area. All machine
parts must be considered to be contaminated when
removed from the hazardous area: suitable meas-
ures must be taken to prevent any dispersal of the
dust. When carrying out maintenance or repairs, it is
essential to dispose of any contaminated objects
that cannot be adequately cleaned. These objects
must be disposed of using impermeable bags and
in accordance with the applicable regulations for
removing such waste.
10.1 General Instructions
Before performing any maintenance, always
switch off the appliance and remove the
mains plug.
Clean the appliance (see section9).
For maintenance by the user, the vacuum cleaner
must be taken apart, cleaned and maintained, to
the extent possible, without endangering mainte-
nance staff or other people.
Preventive Measures
Appropriate preventive measures include:
cleaning the appliance before disassembly;
providing local filtered forced ventilation where the
vacuum cleaner is disassembled; cleaning of the
maintenance area and providing suitable personal
protective clothing and equipment.
10.2 Reduction in suction power
If the suction power decreases, carry out the
following steps:
1. Clean the filter cassettes by activating the elec-
tromagnetic vibrator (set switch (2) to the "IR"
position).
2. Empty the container or replace the paper filter
bag (8)/fleece filter bag (7) or PE filter bag (6).
3. Replace the filter cartridges (18)
10.3 Renew the filter cartridges (18)
Shake the filter cassettes (18) once again before
replacing the filters, by switching on the electro-
magnetic vibrator (set switch (2) to the "IR" posi-
tion).
Use a coin or a similar object to turn the locking
knob (16) on the locking bar (15) counter-clock-
wise through 90° and push the bar (15) to the rear.
Swing up the hood and pull up the filter cartridges
(18) to remove them. Seal the removed filter
cassettes immediately in a dust-tight plastic bag
and dispose of them in accordance with regula-
tions. Insert new filter cartridges, ensuring they are
correctly and securely in place.
10.4 Motor protection filter
Regularly check the motor protection filter. If the
motor protection filter (17) is contaminated, this
indicates that the filter cassettes (18) may be
defective:
- Replace the filter cartridges (18)
- Replace the motor protection filter (17), or rinse it
under running water, dry it and then replace.
10 Servicing
17027067_0711 ASR 35 L_M AutoClean ENTWURF.book Seite 19 Montag, 25. Juli 2011 4:46 16
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Metabo ASR 35 M ACP wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info