8.1 Fault finding
Pump does not run:
No mains voltage.
Check cables, plug, outlet and
mains fuse.
Mains voltage too low.
Use only extension cables with
sufficient lead cross section (see
"Technical Specifications").
Motor overheated, motor protection
relay tripped.
Remove cause for overheating
(fluid pumped too hot? Pump
blocked by foreign objects?)
After cooling off the pump will
switch ON again.
Float switch does not switch the
pump ON.
Ensure a sufficient supply of
water.
Make sure the float switch can
move unrestricted.
Motor hums but does not start:
Pump blocked by foreign object.
Clean pump.
Pump does not pump properly:
Delivery head too high.
Observe max. delivery head (see
"Technical Specifications").
Discharge hose kinked.
Straighten discharge hose.
Discharge hose leaky.
Seal discharge hose, tighten
screw fittings.
Pump runs very noisily:
Pump primes air.
Ensure a sufficient supply of
water.
Adjust float switch correctly.
Hold pump at an angle when sub-
merging.
Pump runs continuously:
Float switch does not reach cut-out
position.
Make sure the float switch can
move unrestricted.
Set to Manual mode, unplug.
A
Danger!
Have your power tool serviced by a
qualified repair person using only
identical replacement parts. This will
ensure that the safety of the power
tool is maintained.
Contact your local Metabo representa-
tive if you have Metabo power tools
requiring repairs. See www.metabo.com
for addresses.
You can download a list of spare parts
from www.metabo.com.
The packaging of the pump can be
100
% recycled.
Worn out power tools and accessories
contain considerable amounts of valua
-
ble raw and plastic materials, which can
be recycled.
These instructions are printed on paper
produced with elemental chlorine free
bleaching process.
9. Repairs
10. Environmental Protection
11. Technical Specifications
TP 7500Si TP 12000Si
Mains voltage V 230 1
Frequency Hz 50
Rated output W 300 600
Rated current A 1.4 2.5
Fuse protection min. (time-lag or L-type circuit breaker) A 10 10
Running capacitor F 8 10
Rated speed min
-1
2800 2800
Pump capacity max. l/h 7500 11700
Delivery head max. m 6.5 9
Delivery pressure max. bar 0.65 0.9
Immersion depth max. m 7 7
Standing water max. mm 3 3
Max. temperature of primed medium °C 35 35
Protection class IP 68 IP 68
Degree of protection I I
Insulation class B B
Materials
Pump casing
Pump shaft
Impeller
Polypropylene
Stainless steel
Noryl
Polypropylene
Stainless steel
Noryl
Power cable (HO 5 RN-F) m 10 10
Discharge port thread (AG = male) 1 1/4" AG 1 1/4" AG
Dimensions (pump casing)
Height
Width
Diameter
mm
mm
mm
285
185
227
320
190
230
Weight kg 4.2 5.1
Max. length of extension cable
at 3 x 1.0 mm
2
lead cross-section
at 3 x 1.5 mm
2
lead cross-section
m
m
60
100
60
100
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Metabo TP 7500 SI wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info