2IR 210 EN
12. Battery Replacement
13. Guarantee
14. Technical Specifications
15. www.microlife.com
Guarantee Card (see Back Cover)
1. The Advantages of this Thermometer
Measurement in 1 second
The innovative infrared technology allows measurement of ear
temperature in only 1 second.
Correct position indication
ACCUsens guidance system confirms the right position in the ear
with «good» displayed on the LCD display and a beep.
Multiple uses (wide range of measurement)
This thermometer offers a wide range of measurement from 0.1-
99.9 °C / 32.2-211.8 °F, meaning the unit can be used to measure
body temperature or it also has a feature allowing it to be used to
measure surface temperature of the following examples:
Milk surface temperature in a baby's bottle
Surface temperature of a baby's bath
Ambient temperature
Probe cover
This thermometer is user-friendly and more hygienic with the
usage of a probe cover.
Probe LED
This thermometer includes a probe LED light which enables the
user to find the correct ear position in the dark.
Accurate and reliable
The unique probe assembly construction incorporates an
advanced infrared sensor, ensuring that each measurement is
accurate and reliable.
Gentle and easy to use
The ergonomic design enables simple and easy use of the ther-
mometer.
This thermometer can even be used on a sleeping child without
causing any interruption.
This thermometer is quick, therefore child-friendly.
Multiple readings recall
Users will be able to recall the last
30
readings with a record of both
time and date when entering the recall mode, enabling efficient
tracking of temperature variations.
Safe and hygienic
No risk of broken glass or mercury ingestion.
Completely safe for use on children.
Using a new probe cover each time, ensures this thermometer
is completely hygienic for use by the whole family.
Fever alarm
10 short beeps and a red LCD backlight alert the patient that he/
she may have a temperature equal to or higher than 37.5 °C.
2. Important Safety Instructions
Follow instructions for use. This document provides important
product operation and safety information regarding this device.
Please read this document thoroughly before using the device
and keep for future reference.
This device may only be used for the purposes described in
these instructions. The manufacturer cannot be held liable for
damage caused by incorrect application.
Never immerse this device in water or other liquids. For
cleaning please follow the instructions in the «Cleaning
and Disinfecting» section.
Do not use this device if you think it is damaged or notice
anything unusual.
Never open this device.
Earwax in the ear canal may cause a lower temperature reading.
Therefore it is important to ensure the subject's ear canal is clean.
Only use this thermometer with a new Microlife branded and
undamaged probe cover to prevent cross-infection.
If the measurement result is not consistent with the patient's
finding or unusually low, repeat the measurement every 15
minutes or double check the result by another core body
temperature measurement.
This device comprises sensitive components and must be
treated with caution. Observe the storage and operating condi-
tions described in the «Technical Specifications» section.
Ensure that children do not use this device unsupervised; some
parts are small enough to be swallowed.
3

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Microlife IR 210 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info