Installation & Owner's Manual
CONTENTS PAGE
1
1
2
4
8
11
14
16
17
18
BASIC OPERATION PRINCIPLE..............................................................
SAFETY INFORMATION..........................................................................
BEFORE INSTALLATION.........................................................................
INSTALLATION......................................................................................
TRIAL-RUNNING....................................................................................
OPERATION ..........................................................................................
TROUBLE SHOOTING.............................................................................
MAINTENANCE......................................................................................
SPECIFICATIONS...................................................................................
MIDEA– HEAT PUMP MANUFACTURER’S WARRANTY..........................
W ARNING
1. SAFETY INFORMATION
Please read thoroughly all of the instrucitons before installing or
operating the unit.
The following safety warnings are very important, always read and
obey all safety symbols:
● The unit must be earthed effectively.
● A RCD breaker must be installed adjacent to the power supply.
Do not remove, cover or deface any permanent instructions,
lables, or the data label from either the outside of the unit or
inside of unit panels.
● Only qualified persons should perform the installation of this unit
in accordance with local national regulations and this manual.
Improper installation may result in water leakage, electric shock
or fire.
Ask qualified person for relocating, repairing and maintaining the
unit.
Improper installation may result in water leakage, electric shock
or fire.
Electric connection work should comply with the instructions of
local power company, local electric utility and this manual.
Never use an incorrectly fuse rated, otherwise the unit may break
down and risk of electrical fire.
● Do not insert fingers, rods or other objects into the air inlet
or outlet. The fan is rotating at high speed, and may cause injury.
● Never use a flammable spray such as hair spray, lacquer paint
near the unit. It may cause a fire.
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance
by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the appliance.
NOTE
Above calculations are based on ideal conditions, the final
amount will be different the actual running will vary with
conditions, such as running period, ambient temperature, etc.
0 1 2 3 4 5 6 7 8 9 10 11 12 13
HPWH
Gas Burner
E-heater
Running Cost AUD
Fig.1-1
0. BASIC OPERATION PRINCIPLE
We know from experience, the natural flow of heat, moves from a
higher to a lower temperature source, a heat pump can transfer heat
from a lower temperature source to a higher temperature source with
high efficiency.
The advantage of a heat pump water heater is that it can supply more
heat energy,
normally 3:1 times than input electricity power by extract-
ing the heat from ambient atmosphere in a free charge way and
transfer to Sanitary Hot Water. Compared to a traditional water heater,
such as electric water heater or gas burner water heater, their
efficiency is normally less than 1:1, which means you can dramatically
cut off the bill of family daily SHW by the application of heat pump
water heater, the following examples will show more details.
Power consumption comparison under the same condition to heat 1
ton of water from 15˚C to 55˚C.
The equivalent heat load Q=CM(T1-T2)=1(kCal/kg*)X1000(kg)
X(55-15)()=40000kCal=46.67kW*h
Table 0-1
HPW H Gas Burner E-heater
Energy
Resourc
e
Air,Electricity Gas Electricity
Transfer Factor 860kCal/kW*h
8905kCal/m
³
860kCal/kW*
h
Average
Efficienc
y
(W/W)
3.5 0.8 0.95
Unit Cost 0.25 AUD/kW*h
1.7C/MJ
0.25 AUD/kW
*
h
Running Co
t
AUD
12.28 3.57 3.33
13.33kW*h 210MJ 49.13 kW*
h
Energy
Consumptio
n
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Midea RSJ-35 - 300RDN3 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Midea RSJ-35 - 300RDN3

Midea RSJ-35 - 300RDN3 Bedienungsanleitung - Holländisch - 27 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info