ROYAL evo 7 - Instructions
Page 47
ENGLIS
H
16.2.2. Free assignment with model helicopters
If you have set up a model helicopter based on one of
the model templates HELImech or HELIccpm, various
transmitter controls can be selected for the free or vari-
able channels. You can find out which channels are free
or variable by consulting the descriptions of the heli-
copter model templates (Î 20. onward):
Available
controls
Note
Pitch-ax
Pitch-axis signal only no mixing
Yaw
Yaw signal only no mixing
Throttle
Throttle signal, plus mixed throttle curve,
throttle limiter, direct throttle, EMERGENCY
throttle CUT
Spoiler
Spoiler signal only no mixing
RPM
Control signal for speed controller
L. gear
Retract signal no mixing
Aero-tow
Aero-tow signal mixing
Brake
Brake signal mixing
Gyro
Gyro signal, including all mixed signals
from the
Gyro mixer
Mixture
Mixture signal only no mixing
AUX1
AUX2
AUX1/2 signal only no mixing
Coll. P.
Coll. pitch signal only no mixing
16.2.3. Special features when assigning
The transmission mode PPM 6 or PPM 7 is set automati-
cally:
Last servo on channel 6 PPM 6
Last servo on channel 7 PPM 7
Problems may occur with PPM 6 and certain older types
of speed controller, in which case it may help to assign
any function to channel 7. This forces PPM 7 operation;
you do not need to connect a servo to the output.
16.3. Sub-menu: Monitor
The Servo Monitor is a substitute for a receiving system
and servos, enabling you to check the function and op-
eration of servos, speed controllers and - especially -
gyro systems (for which an external effect is not easy to
detect), and seek and eliminate faults.
Call up the menu, then press the ENTER button or a 3D
digi-adjustor; the Servo Monitor then appears.
Two display variants are available:
x graphic, with bar-form display of output signals
(Fig. 1), and
x numerical, with display of % values (Fig. 2).
You can switch between the two displays using the UP /
DOWN buttons ( / ) or one of the two 3D digi-
adjustors.
Press the ENTER button or one of the 3D digi-adjustors
to close the Servo Monitor.
16.4. Sub-menu: Test run
Automatic servo run, designed for test and demonstra-
tion purposes or as an “electronic aid” for range-
checking.
As soon as you select a transmitter control, the transmit-
ter generates a constant control signal with variable
transit time, i.e. from one end-point of the control to the
other. All servos which are operated by this transmitter
control, either directly or via a mixer, start running.
You can interrupt the test run by either of two methods:
x Press the REV/CLR button “ Control
“ appears
x Select no transmitter control (“ - - - - - - - “)
The transit time can be set to any value in the range 0.1
– 4.0 seconds.
17.Main Menu Timer A
The ROYALevo7 features a stopwatch with alarm func-
tion which can be used for various timing tasks. The
stopwatch counts up to 4½ hours with a resolution of
one second.
Line 1:
Time
This is the time which has elapsed since the timer
started. If you select this field, you can erase the time
using the REV/CLR button.
The stopwatch can also be reset by pressing the
REV/CLR button when you are in one of the status dis-
plays 1 - 3.
Line 2:
Alarm
This is where you set the alarm time. For example, if the
motor run of an electric-powered model is four minutes,
you should set
0:04:00 at this point. The timer adds
together the motor run time based on the throttle set-
ting, and emits a warning sound once the set alarm time
has elapsed.
The method of entering the alarm time differs from the
usual procedure: here the value is entered digit by digit:
press the ENTER button or one of the 3D digi-adjustors.
The cursor jumps to the hours, which can then be set
using the UP / DOWN buttons or one of the 3D digi-
adjustors. Every time you press ENTER again, the cursor
moves one place to the right etc.
48

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Multiplex ROYALevo7 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Multiplex ROYALevo7

Multiplex ROYALevo7 Bedienungsanleitung - Deutsch - 77 seiten

Multiplex ROYALevo7 Bedienungsanleitung - Holländisch - 110 seiten

Multiplex ROYALevo7 Bedienungsanleitung - Französisch - 77 seiten

Multiplex ROYALevo7 Bedienungsanleitung - Italienisch - 75 seiten

Multiplex ROYALevo7 Bedienungsanleitung - Spanisch - 76 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info