In the standard clock program for the weather dependent
regulation you do not find temperatures, but scale points. One
point of the scale corresponds with a temperature range of
0.5 °C to 2 °C.The calculation starts at 0, which corresponds
with a standard room temperature (20 °C).
Consequently:
– 1 means 18 - 19.5°C and
+ 1 means 20.5 - 22°C.
1 point does not
correspond with 1 °C.
Where setting or changing of the temperature is mentioned
in the text, you must change the scale points for the
weather dependent regulation.This is possible with
steps of 0.5 points.
4.5 Your own clock program
Instead of using the standard clock program, it is also possible to
create your own clock program. In doing so, you can create a
clock program appropriate for your daily schedule. For each
switching point you can adapt the time and the temperature.
Furthermore, you can insert or remove switching points.
Changing a switching point
1. Make sure the display is in normal mode (refer to figure 3-2)
2. Select the switching point you want to change, using the
program knob.
3. Change the time as follows:
- Press and hold the TIME key.
- Change the time using the program knob.
- Release the TIME key.