English - 37
English
Configuration and calibration of the IRT 30 thermostat
3. In the middle of the display, the temperature to which the
temperature adjustment knob is set, is shown. On the right
side, a blinking temperature, which you can alter, is shown.
4. Turn the program knob, while holding the MENU and
REMOVE keys, until the blinking temperature reflects the
temperature onto which the temperature adjustment knob is
set.
5. Release all keys when you are finished.
Calibration of the outside temperature sensor
The outside temperature sensor should be calibrated when the
measured temperature shown on the display, deviates from the
actual outside temperature at the outside temperature sensor.
Note: The outside temperature sensor can only be calibrated when it
is connected to the boiler, and the weather dependent
regulation (WD or WD + RTC) has been set.
You can calibrate the outside temperature sensor as follows:
1. Make sure the display is in normal mode (refer to figure 3-2).
2. Simultaneously press the MENU and REMOVE keys three
times and hold them.To the right on the display, the TEMP-
BUITEN symbol appears.
In the middle of the display, the temperature to which the
temperature adjustment knob is set, is shown. On the right
side, a blinking temperature, which you can alter, is shown.
3. Turn the program knob, while holding the MENU and
REMOVE keys, until the blinking temperature reflects the
actual outside temperature.
4. Release all keys when you are finished.