• Trouble-shooting Guide
Important note: when working on the operator, always pull out the mains plug beforehand!!!
Malfunction Possible causes Remedy
Door does not open / close fully. Door mechanics have altered. Have the door checked.
Door does not open / close fully. Set the forces (menu stages 5 and 6).
Travel limit is incorrectly set. Reset travel limit .
After closing, the door opens again slightly. Door blocks shortly before reaching the closed Remove the obstruction.
position. Reset closed travel limit .
Travel limit is incorrectly set.
Door fails to move although the motor is Operator is not engaged. Re-engage the operator 24c.
running.
Door does not respond on impulse from the Battery in the hand transmitter is flat. Replace battery in the hand transmitter.
hand transmitter - but does respond to push- Aerial not available or not fitted. Plug in / align aerial.
buttons or other impulse generators. No hand transmitter programmed. Programme the hand transmitter ( menu
stage 1).
Door does not respond to impulse from hand See diagnostic display. See diagnostic display.
transmitter nor to other impulse generators.
Insufficient range of hand transmitter. Battery in the hand transmitter is flat. Replace battery in the hand transmitter.
Aerial not available or not fitted. Plug in / align aerial.
On-site screening of the receiving signal. Connect external aerial (accessories).
Toothed belt or operator noisy. Toothed belt dirty. Clean toothed belt.
Tension of toothed belt too high. Spray with silicone.
Detension the toothed belt.
18
18
15
GB
Diagnostic display
During operation, the display provides diagnostic information on any possible faults / malfunctions
Number State Diagnosis / Remedy
_______________________________________________________________________________________________________________________
Operator starts up and “0” goes out. Operator receives a start impulse at the START input or via a receiver,
normal operation.
_________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
0 displayed during the next opening and closing cycle Operator is carrying out a learning cycle for the force limit.
and then goes out. Caution: During these travel cycles the force is not monitored!
_________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
0 continues to be displayed.
_________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Door neither opens nor closes. STOP A connection is interrupted.
External safety device has been activated (e.g. wicket door).
_________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Door no longer closes. STOP B connection is interrupted.
External safety device has been activated (e.g. photocell).
_________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Permanent impulse signal at the start input. Door no longer accepts a start impulse. External impulse generator emits a
permanent impulse signal (e.g. button is jammed)
_________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
An error ocurred in setting the operator. Travel path too long.
Repeat setting procedure (menu stages 3 and 4).
_________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Closing edge OSE has been activated. Check closing edge, spiral cable and optics.
F (menu stages 3 and 4)
or wicked door contact has been activated.
__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Door neither opens nor closes.
_________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Motor has come to a standstil. Motor does not rotate. Call in a specialist company.
_________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
V
Top end-of-travel position Open has been reached.
Bottom end-of-travel position Closed has been reached.
Gate end position has not been reached.
Force-learning cycle not completed. Must be repeated.
Too much pressure in the gate's end-of-travel positions. Gate setting required.
Gate setting und learning cycle not correctly finalized. Repeat gate setting in menus 3 & 4 and complete force-learning cycle
subsequently.
ault during learning cycle. Repeat position learning cycle.
Reduce force when approaching the end-of-travel positions.
Emergency release has been activated Operator is released, lock the coupling again 24c.
Check wicket door contact.
Fault during self-test. Disconnect power supply.
acation lock activated, gate does not open. Slide switch at SafeControl / Signal 112 confirmed. Reset required.
Deleting radio codes
Press oval key. Keep key pressed while inserting power plug.
All radio codes stored in the hand-held transmitter are now deleted.
Restoring factory setting
Press Open and Close keys at the same time. Keep keys pressed for approx. 3 sec while inserting
power plug.
The factory setting has been restored.
20

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Novoferm NovoPort LED wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info