709129
18
Zoom out
Zoom in
Vorherige Seite
1/43
Nächste Seite
displayed.
Press the second button at the transmitter with which
the 4-min light is to be switched on. As soon as the
code has been read in, the red point display (a) will
flash 5 times to acknowledge the entry. Figure 0 will
be displayed. Menu finished.
Deleating all the hand transmitters programmed
for the operator:
Plug in the operator‘s main plug while pressing
button .
Menu stage 3: Setting / adjusting the top end-
of-travel position
Keep button pressed for 3 seconds. Number 3
appears in the display 8 a.
Wait a short while until the 3 starts flashing.
Press button and make sure that the door travels in
the OPEN direction.
If the door closes in the wrong direction, after
having pressed , keep button pressed for
!
another 3 seconds. “3” flashes briefly. The
travelling direction is altered.
Now travel by pressing button into the desired door
end position OPEN 17b.
By pressing button , the position can be corrected
into direction CLOSE.
Once the desired OPEN end-of-travel position has
been reached, press button . The operator stores
the OPEN end-of-travel position and “4” appears in
the display.
Menu stage 4: Setting / adjusting the bottom
end-of-travel position
Wait a short while until “4” starts flashing.
Press button . The operator causes the door to
travel in the CLOSE direction as long as the button is
pressed. The position can be altered to the OPEN
direction via button ..
Once the desired CLOSE end-of-travel position has
been reached, press button . The operator stores
the CLOSE end-of-travel position and “5” appears in
the display.
Press button twice until “0” appears.
Force-learning cycle
We recommend setting the suitable door type in
!
menu stage 8 prior to the force-learning cycle.
During this opening and closing cycle, the
operator learns the force required to open and close
the door. A force limit does not apply! The cycles
must not be interrupted. During these cycles must
not be interrupted. During these cycles “0” appears
in the display.
- Press button . The operator causes the door to
open until the top end-of-travel position has been
reached.
- Now press button again. The operator causes
the door to close until the bottom end-of-travel
position has been reached.
- After approx. 2 seconds, “0”disappears.
Checking the force limit device
- Position the force-measuring device
(dynamometer) in the closing area.
(If a measuring device is not available, use, for
example, the operators cardboard box)
- Start the door from the OPEN end-of-travel
position.
- The door travels towards the obstruction, stops
and re-opens.
If the door springs were altered, the force-learning
operation must then be repeated:
Call up menu stage 5 and keep button depressed
17
18
19
20
for 3 seconds. A "0" is displayed. Then carry out
force-learning operations as explained under point
19.
Special settings
Menu stage 5: The opening force limit
If you have previously quit the setting menu, press
button for 3 seconds until “3” appears. Then press
button twice until “5” appears.
After approx. 2 seconds, the display flashes showing
the set value of the opening force limit. The force limit
setting can be increased for decreased via buttons
and . After setting the value, press button .
The display shows “6”.
Menu stage 6: The closing force limit
After approx. 2 seconds, the display starts flashing,
and the set value for the closing force limit is
displayed.
The force limit setting can be increased or decreased
via buttons and .
After setting the value, press button . “0” appears
in the display.
Finally, check the force settings, and, if necessary,
repeat the setting procedure.
The maximum force at the main closing edge must
not exceed 150 N!
Menu stage 7: Light phases
Keep button pressed for 3 seconds. A "3" is
displayed. Press button repeatedly until menu 6
is displayed. Keep button pressed again for 3
seconds until a "7" is displayed.
Menu Light Warning 24V
value phase phase
0 60 s - 60 s
1 120 s - 120 s
2 240 s - 240 s
3 0 s - 0 s
4 0 s 3 s 0 s
5 60 s 3 s 0 s
6 120 s 3 s 0 s
7 60 s 0 s TAM
8 120 s 0 s TAM
9 240 s 0 s TAM
The factory setting is 1.
TAM: OPEN signal, when the door is not closed 24V
are available for signalling.
Menu stage 8: Door fitting
Press button . “8” appears in the display.
Menu Start Stop Start Stop
value open open closed closed
1 15 0 15 0
4 25 30 25 40
5 15 15 15 55
6 15 15 15 15
7 35 35 65 45
8 55 15 15 100
9 only soft run
These values correspond to the soft” runs
measured in cm at the carriage.
In order to access the menus for the special settings,
keep key pressed for 3 sec until figure 3 is
displayed. Press key to by-pass menu step 3.
Now keep key pressed for 3 sec until figure 5 is
displayed. Press key to by-pass menu steps.
When the advance warning time is set, the light and
24 V will be switched on before the drive starts
running.
0 0 0 0 0
2 0 15 0 40
3 15 15 15 35
Menu stage 9: special functions
Push button .“9” is displayed.
Menu Operating mode
value
0 Normal operation
1 Normal operation with ventilation
position
The ventilation position can be initiated by
pressing the second push button on the
hand transmitter or via the signal 112
internal push button (accessory).
2 Partial opening of side sectional doors
Partial opening of approx. 1m can be
initiated by pressing the second push
button on the hand transmitter or via the
signal 112 internal push button
(accessory).
Advice: The 2nd push button of the transmitter has
to be teached-in again after changing the operation
mode.
Internal impulse generators
The cover on the control unit is used as an impulse
generator for opening and closing from inside the
garage. Briefly press the cover and the operator
starts up .
Disengagement
The operator is equipped with a quick release. By
pulling the pull cord with knob 22a, the operator can
be permanently disengaged from the door 22b. “8” is
displayed.
The motor head can be re-engaged at any point
between the two limit switch actuators. To lock in
place, press down lever 22c.
Installation on LH side of door
If favoured by the structural conditions on site, the
operator can also be installed on the left-hand side
ck on the other side 23c.
23a. Loosen bolts on motor head with wrenches (SW
10 and 17mm) 23b and screw them back on the
other side 23c.
Low-mounted control unit
If the control unit cannot be positioned directly
underneath the track 24a, the coiled cable can then
be routed to the motor head using the supplied
second cable clamp and the punched tape 24b. The
extendible part of the coiled cable may be stretched
by a maximum of factor 3 and the permanently laid
part by a maximum of factor 7.
If the coiled cable is not long enough, the extension
set (accessory) should be used.
Connection for wicket door contact
The option of connecting the wicket door contact
to drive unit is an advantage.
- Remove housing 25a.
- On the white plastic component, break out the
side wall towards the door 25b.
- Route cable from wicket door contact over the
lifting arm and fasten with cable binder 25c.
- Remove jumper from terminal block 25d and
insert cable 25e.
- Place housing back on again and screw down
25f.
Check: Open wicket door, "8" is displayed.
21
22
23
24
25
Retain these installation, operating and maintenance instructions for the full duration of the operators service life!
GB
18

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Novoferm NovoPort LED wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info